Stress Distribution on Short Implants with Varying Crown Heights - An Study.

Annapoorni Hariharan, A Krithika, K Thanya, C Thamarai, Devi Parameswari, S Dhevishri
Author Information
  1. Annapoorni Hariharan: Department of Prosthodontics and Crown and Bridge, Meenakshi Ammal Dental College and Hospital, Maduravoyal, Chennai, Tamil Nadu, India.
  2. A Krithika: Department of Prosthodontics and Crown and Bridge, Meenakshi Ammal Dental College and Hospital, Maduravoyal, Chennai, Tamil Nadu, India.
  3. K Thanya: Department of Prosthodontics and Crown and Bridge, Meenakshi Ammal Dental College and Hospital, Maduravoyal, Chennai, Tamil Nadu, India.
  4. C Thamarai: Department of Prosthodontics and Crown and Bridge, Meenakshi Ammal Dental College and Hospital, Maduravoyal, Chennai, Tamil Nadu, India.
  5. Devi Parameswari: Department of Prosthodontics and Crown and Bridge, Meenakshi Ammal Dental College and Hospital, Maduravoyal, Chennai, Tamil Nadu, India.
  6. S Dhevishri: Postgraduate, Department of Prosthodontics and Crown and Bridge, Meenakshi Ammal Dental College and Hospital, Maduravoyal, Chennai, Tamil Nadu, India.

Abstract

The aim of this study is to determine the stress in short implants loaded with varying crown heights using a 3D finite element analysis. A total of three mandibular sectional bone blocks depicting the mandibular left first molar region were modeled. Each block carried Bicon implants of the same size and was designated B1, B2, and B3. The implant- crown ratio is 1:1.5, 1:2.5, and 1:3 respectively. The loading protocol included axial and oblique loads. The von Misses' equivalent stresses at the implant-bone interface were evaluated. Intergroup comparison was determined using one-way ANOVA analysis, and P values were calculated. Under an axial load of 600N, the models B1, B2, and B3 do not show any statistically significant P-values at the crestal module of the implant, abutment, and bone, whereas in crowns, the P-values were highly significant. Under an oblique load of 225 N at 0°, 45°, and 90°, model B3 showed the highest values in the crestal module, abutment, and crown. Based on the intergroup comparison and P value the study concluded that the variance in the crown height does not affect the bone and therefore microfracture of the bone and failure of osseointergration is not likely.

Keywords

References

J Dent Res Dent Clin Dent Prospects. 2019 Spring;13(2):85-89 [PMID: 31592304]
J Oral Implantol. 2010;36(6):425-33 [PMID: 20545533]
Int J Oral Maxillofac Implants. 2016 May-Jun;31(3):672-5 [PMID: 27183087]
Dent Res J (Isfahan). 2021 Feb 23;18:1 [PMID: 34084288]
J Biomech. 2015 Jan 2;48(1):138-45 [PMID: 25435384]
Niger J Clin Pract. 2019 Sep;22(9):1252-1258 [PMID: 31489862]
J Prosthet Dent. 2001 Jun;85(6):585-98 [PMID: 11404759]
BMC Oral Health. 2023 May 16;23(1):298 [PMID: 37194034]
Clin Oral Implants Res. 2009 Sep;20 Suppl 4:67-72 [PMID: 19663952]
Int J Implant Dent. 2021 Sep 1;7(1):81 [PMID: 34467461]
BMC Oral Health. 2023 Sep 20;23(1):683 [PMID: 37730562]
Clin Oral Implants Res. 2018 Oct;29 Suppl 18:243-252 [PMID: 30306696]
J Prosthodont. 2009 Feb;18(2):116-22 [PMID: 19254301]
Clin Oral Investig. 2020 Sep;24(9):3213-3222 [PMID: 32681422]
Dent Res J (Isfahan). 2019 May-Jun;16(3):200-207 [PMID: 31040877]
J Prosthet Dent. 2015 Jun;113(6):548-57 [PMID: 25794917]
J Oral Implantol. 1991;17(2):126-31 [PMID: 1811063]
Eur J Oral Sci. 1998 Jun;106(3):721-64 [PMID: 9672097]

Word Cloud

Similar Articles

Cited By