Laser light scattering spectroscopy: a new method to measure tracheobronchial mucociliary activity.

K Svartengren, L G Wiman, P Thyberg, R Rigler
Author Information
  1. K Svartengren: Department of Lung Medicine, Karolinska Institute, Huddinge University Hospital, Sweden.

Abstract

Laser light scattering spectroscopy is based on the evaluation of the frequency shift of coherent light scattered by moving particles. This makes it particularly suitable for use in light guiding systems. In this study laser light scattering spectroscopy was assessed for its ability to provide information on the motility of respiratory cilia. In vitro and in vivo measurements were undertaken with animal tracheal mucosa. The intensity fluctuations of laser light scattered from moving cilia were analysed in terms of their autocorrelation functions to provide information on the frequency and synchrony of beating cilia. In vitro measurements were performed on fresh bovine trachea to estimate a safe laser power level for mucosal exposure and to test the method by defining the temperature dependence of the ciliary beat frequency. Power densities not exceeding 0.3 kW/cm2 were found to be the upper limit for long term exposure of the mucosa in vitro. Ciliary beat frequency showed a pronounced temperature dependence, ranging from 5.8 to 28.3 Hz over the temperature range 20-43.5 degrees C. A maximum frequency was found at 41.5 degrees C. In vivo measurements of ciliary activity were performed in six pigs by means of optical fibres for light transmission combined with fibreoptic bronchoscopy. A ciliary beat frequency of 5 Hz was obtained; heart and breathing frequencies could be separated and identified. These results suggest that laser light scattering spectroscopy might provide a convenient method of studying the mucociliary system of the lower airways.

References

  1. Exp Cell Res. 1981 Sep;135(1):147-56 [PMID: 7286076]
  2. Acta Otolaryngol. 1974 Jul-Aug;78(1-2):118-23 [PMID: 4411664]
  3. Ann Biomed Eng. 1977 Sep;5(3):248-59 [PMID: 921017]
  4. Acta Physiol Scand Suppl. 1956;36(123):1-161 [PMID: 13326492]
  5. Acta Otolaryngol. 1977 May-Jun;83(5-6):491-7 [PMID: 888685]
  6. Zentralbl Veterinarmed A. 1970 Nov;17(9):796-802 [PMID: 4997502]
  7. Eur J Respir Dis Suppl. 1983;127:129-36 [PMID: 6604645]
  8. Clin Sci (Lond). 1980 Aug;59(2):79-84 [PMID: 6996900]
  9. Cytometry. 1984 Jul;5(4):327-32 [PMID: 6468172]
  10. J Appl Physiol. 1975 May;38(5):946-8 [PMID: 1126911]
  11. J Appl Physiol Respir Environ Exerc Physiol. 1980 May;48(5):868-71 [PMID: 7451296]
  12. Acta Otolaryngol. 1982 Jan-Feb;93(1-2):151-9 [PMID: 7064691]
  13. Am Rev Respir Dis. 1977 Jul;116(1):73-125 [PMID: 327882]
  14. Acta Otolaryngol. 1974 Nov-Dec;78(5-6):444-50 [PMID: 4451095]
  15. J Appl Physiol. 1973 Apr;34(4):495-9 [PMID: 4698607]
  16. Eur J Respir Dis. 1986 Feb;68(2):107-13 [PMID: 3699113]
  17. Acta Otolaryngol. 1978 Sep-Oct;86(3-4):283-8 [PMID: 707069]
  18. Am Rev Respir Dis. 1980 Apr;121(4):661-5 [PMID: 7386979]
  19. Med Res Eng. 1977 Feb;12(4):19-25 [PMID: 329040]

MeSH Term

Animals
Bronchi
Cattle
In Vitro Techniques
Lasers
Light
Mucociliary Clearance
Scattering, Radiation
Spectrum Analysis
Swine
Trachea

Word Cloud

Created with Highcharts 10.0.0lightfrequencyscatteringlaser5spectroscopyprovideciliavitromeasurementsmethodtemperatureciliarybeatLaserscatteredmovinginformationvivomucosaperformedexposuredependence3foundHzdegreesCactivitymucociliarybasedevaluationshiftcoherentparticlesmakesparticularlysuitableuseguidingsystemsstudyassessedabilitymotilityrespiratoryundertakenanimaltrachealintensityfluctuationsanalysedtermsautocorrelationfunctionssynchronybeatingfreshbovinetracheaestimatesafepowerlevelmucosaltestdefiningPowerdensitiesexceeding0kW/cm2upperlimitlongtermCiliaryshowedpronouncedranging828range20-43maximum41sixpigsmeansopticalfibrestransmissioncombinedfibreopticbronchoscopyobtainedheartbreathingfrequenciesseparatedidentifiedresultssuggestmightconvenientstudyingsystemlowerairwaysspectroscopy:newmeasuretracheobronchial

Similar Articles

Cited By