Mathematical basis for the measurement of absolute and fractional cardiac output with diffusible tracers by compartmental analysis methods.

N D Charkes
Author Information

Abstract

Using compartmental analysis methods, a mathematical basis is given for the measurement of absolute and fractional cardiac output with diffusible tracers. Cardiac output is shown to be the product of the blood volume and the sum of the rate constants of tracer egress from blood, modified by a factor reflecting transcapillary diffusibility, the transfer fraction. The return of tracer to the blood and distant (intracellular) events are shown to play no role in the solution. Fractional cardiac output is the ratio of the rate constant of tracer egress from blood to an organ, divided by the sum of the egress constants from blood. Predominantly extracellular ions such as sodium or bromide are best suited for this technique, although theoretically any diffusible tracer whose compartmental model can be solved may be used. It is shown that fractional cardiac output is independent of the transfer fraction, and therefore can be measured accurately by tracers which are not freely diffusible.

References

  1. J Nucl Med. 1979 Dec;20(12):1257-61 [PMID: 536792]
  2. J Nucl Med. 1980 Jul;21(7):641-5 [PMID: 7391837]
  3. Am J Physiol. 1958 Apr;193(1):161-8 [PMID: 13521003]
  4. Am J Physiol. 1964 Oct;207:767-70 [PMID: 14220059]
  5. J Nucl Med. 1978 Dec;19(12 ):1301-9 [PMID: 731317]
  6. Clin Sci Mol Med. 1974 Jul;47(1):73-7 [PMID: 4855089]
  7. Am J Physiol. 1952 Aug;170(2):401-13 [PMID: 12985909]
  8. Ann N Y Acad Sci. 1965 Sep 8;127(1):393-413 [PMID: 5217272]
  9. Fed Proc. 1977 Nov;36(12):2634-9 [PMID: 913623]
  10. J Appl Physiol. 1955 Mar;7(5):542-8 [PMID: 14367244]
  11. J Nucl Med. 1979 Nov;20(11):1150-7 [PMID: 536775]

MeSH Term

Animals
Cardiac Output
Diffusion
Diphosphonates
Humans
Mathematics
Models, Biological
Regional Blood Flow
Technetium
Technetium Tc 99m Medronate

Chemicals

Diphosphonates
Technetium
Technetium Tc 99m Medronate

Word Cloud

Created with Highcharts 10.0.0outputbloodcardiacdiffusibletracercompartmentalfractionaltracersshownegressanalysismethodsbasismeasurementabsolutesumrateconstantstransferfractioncanUsingmathematicalgivenCardiacproductvolumemodifiedfactorreflectingtranscapillarydiffusibilityreturndistantintracellulareventsplayrolesolutionFractionalratioconstantorgandividedPredominantlyextracellularionssodiumbromidebestsuitedtechniquealthoughtheoreticallywhosemodelsolvedmayusedindependentthereforemeasuredaccuratelyfreelyMathematical

Similar Articles

Cited By