[Pediatric fiberoptic bronchoscopy via the laryngeal mask airway].

Y Fukushima, T Yorozu, M Satoh, H Eguchi, T Shigematsu
Author Information
  1. Y Fukushima: Department of Anesthesiology, Tokyo Metropolitan Ohtsuka Hospital.

Abstract

Fiberoptic bronchoscopy was performed on 11 children aged from 6 months to 3 years and weighing between 2.1 and 12.5 kg using the laryngeal mask airway (LMA). The LMA allows observation of subglottic stenosis which can not be seen under tracheal intubation. The smaller prototype of the fiberoptic bronchoscope whose diameter is 1.8mm has no provision for angulation at the tip. However, using the LMA as a guide it was easy to reach the subglottic stenosis even using this smaller bronchoscope.

MeSH Term

Anesthesia, General
Bronchoscopy
Child, Preschool
Fiber Optic Technology
Glottis
Humans
Infant
Laryngeal Masks
Laryngostenosis

Word Cloud

Created with Highcharts 10.0.0usingLMAbronchoscopy1laryngealmasksubglotticstenosissmallerfiberopticbronchoscopeFiberopticperformed11childrenaged6months3yearsweighing2125kgairwayallowsobservationcanseentrachealintubationprototypewhosediameter8mmprovisionangulationtipHoweverguideeasyreacheven[Pediatricviaairway]