Pneumothorax detection using pulmonary acoustic transmission measurements.

H A Mansy, T J Royston, R A Balk, R H Sandler
Author Information
  1. H A Mansy: Biomedical Acoustics Research Group, Department of Pediatrics, Rush Medical College, Chicago, USA. hmansy@rush.edu

Abstract

Pneumothorax is a common clinical condition that can be life threatening. The current standard of diagnosis includes radiographic procedures that can be costly and may not always be readily available or reliable. The objective of this study was to investigate the hypothesis that pneumothorax causes detectable pathognomonic changes in pulmonary acoustic transmission. An animal model was developed whereby 15 mongrel dogs were anaesthetised, intubated and mechanically ventilated. A thoracoscopic trocar was placed into the pleural space for the introduction of air and confirmation of a approximately 30% pneumothorax by direct visualisation. Broadband acoustic signals were introduced into the endotracheal tube, while transmitted waves were measured at the chest surface. Pneumothorax was found consistently to lower the pulmonary acoustic transmission in the 200-1200 Hz frequency band, whereas smaller transmission changes occurred at lower frequencies (p< 0.0001, sign test). The ratio of acoustic energy between low-(< 220 Hz) and high-(550-770 Hz) frequency bands was significantly different in the control and pneumothorax states (p < 0.0001, sign test). This implies that pneumothoraces can be reliably detected using pulmonary acoustic transmission measurements in the current animal model. Further studies are needed to investigate the feasibility of using this technique in humans.

References

  1. Crit Care Med. 1991 Jul;19(7):906-10 [PMID: 2055079]
  2. Am Rev Respir Dis. 1983 Sep;128(3):451-4 [PMID: 6614639]
  3. J Acoust Soc Am. 2002 Apr;111(4):1931-46 [PMID: 12002875]
  4. N Engl J Med. 2000 Mar 23;342(12):868-74 [PMID: 10727592]
  5. AJR Am J Roentgenol. 1985 May;144(5):901-5 [PMID: 3872573]
  6. Am J Clin Pathol. 1978 Jul;70(1):24-6 [PMID: 696669]
  7. IEEE Trans Biomed Eng. 1989 Sep;36(9):925-34 [PMID: 2777281]
  8. Chest. 1994 Apr;105(4):1147-50 [PMID: 8162741]
  9. Br J Dis Chest. 1980 Jan;74(1):23-31 [PMID: 7356911]
  10. Pediatrics. 1984 Nov;74(5):813-9 [PMID: 6493875]
  11. J Am Coll Surg. 1994 May;178(5):466-70 [PMID: 8167883]
  12. Chest. 1987 Apr;91(4):608-13 [PMID: 3549176]
  13. IEEE Trans Biomed Eng. 1992 Oct;39(10):1053-9 [PMID: 1452171]
  14. Chest. 2001 Feb;119(2):590-602 [PMID: 11171742]
  15. J Appl Physiol. 1952 Jun;4(12):886-900 [PMID: 14946086]
  16. J Appl Physiol (1985). 1990 Dec;69(6):2126-30 [PMID: 2077010]
  17. World J Surg. 1998 Aug;22(8):803-6 [PMID: 9673550]
  18. Med Biol Eng Comput. 2001 Mar;39(2):159-67 [PMID: 11361241]

Grants

  1. 1 R43 HL61108-01/NHLBI NIH HHS
  2. R21-RR14250/NCRR NIH HHS

MeSH Term

Acoustics
Animals
Dogs
Lung
Pneumothorax
Signal Processing, Computer-Assisted
Sound Spectrography
Stethoscopes

Word Cloud

Created with Highcharts 10.0.0acoustictransmissionpulmonaryPneumothoraxcanpneumothoraxHzusingcurrentinvestigatechangesanimalmodellowerfrequency00001signtest<measurementscommonclinicalconditionlifethreateningstandarddiagnosisincludesradiographicprocedurescostlymayalwaysreadilyavailablereliableobjectivestudyhypothesiscausesdetectablepathognomonicdevelopedwhereby15mongreldogsanaesthetisedintubatedmechanicallyventilatedthoracoscopictrocarplacedpleuralspaceintroductionairconfirmationapproximately30%directvisualisationBroadbandsignalsintroducedendotrachealtubetransmittedwavesmeasuredchestsurfacefoundconsistently200-1200bandwhereassmalleroccurredfrequenciesp<ratioenergylow-220high-550-770bandssignificantlydifferentcontrolstatespimpliespneumothoracesreliablydetectedstudiesneededfeasibilitytechniquehumansdetection

Similar Articles

Cited By