Trap for MAbs: characterization of intact monoclonal antibodies using reversed-phase HPLC on-line with ion-trap mass spectrometry.

John C Le, Pavel V Bondarenko
Author Information
  1. John C Le: Department of Pharmaceutics and Drug Delivery, Amgen Inc., Thousand Oaks, California 91320-1789, USA. johnl@amgen.com

Abstract

For the first time, the characterization of intact 150-kDa monoclonal antibodies (MAbs) using a commercially available three-dimensional ion-trap mass spectrometer (IT-MS) is reported. The IT-MS analysis was performed on-line with reversed-phase high performance liquid chromatography (RP-HPLC) on a POROS column using a nontraditional solvent system of acetonitrile, isopropanol, ethanol, and water in formic acid. The operating parameters of the IT-MS were optimized by extending the mass range to m/z 4000 and elevating the tube lens offset voltage value to around -100 V. Mass accuracy better than 300 ppm (+/-40 Da) has been routinely achieved for these macromolecules. Multiple peaks 162 Da apart due to the hexose variants of the monoclonal IgG antibodies were partially resolved in mass spectra. Several commercial and chimeric antibodies have been investigated in this study.

References

  1. Anal Chem. 1995 Oct 15;67(20):3626-32 [PMID: 8644915]
  2. Immunol Today. 2000 Aug;21(8):397-402 [PMID: 10916143]
  3. J Chromatogr A. 2004 Oct 22;1053(1-2):299-305 [PMID: 15543996]
  4. J Chromatogr A. 1995 Sep 29;712(1):177-90 [PMID: 8556150]
  5. Bioconjug Chem. 1996 Jan-Feb;7(1):16-22 [PMID: 8741986]
  6. Anal Chem. 1996 Jan 1;68(1):1-8 [PMID: 8779426]
  7. J Chromatogr B Biomed Sci Appl. 2001 Mar 10;752(2):233-45 [PMID: 11270864]
  8. J Mass Spectrom. 2000 Apr;35(4):493-503 [PMID: 10797646]
  9. J Chromatogr A. 2001 Aug 24;927(1-2):61-76 [PMID: 11572399]
  10. Anal Chem. 1994 Jan 1;66(1):126-33 [PMID: 8116874]
  11. J Am Soc Mass Spectrom. 1994 May;5(5):350-8 [PMID: 24222589]
  12. Anal Chem. 1995 Oct 15;67(20):3613-25 [PMID: 8644914]
  13. Biochemistry. 1997 Dec 2;36(48):14914-23 [PMID: 9398215]
  14. Anal Chem. 1994 Mar 1;66(5):585-95 [PMID: 8154587]
  15. Biophys J. 2001 Dec;81(6):3503-9 [PMID: 11721011]
  16. FEBS Lett. 2000 May 19;473(3):349-57 [PMID: 10818239]
  17. Science. 1989 Oct 6;246(4926):64-71 [PMID: 2675315]
  18. J Am Soc Mass Spectrom. 1994 Feb;5(2):64-71 [PMID: 24222517]
  19. Anal Chem. 2003 Apr 15;75(8):1805-11 [PMID: 12713037]
  20. Anal Chem. 1995 Oct 15;67(20):3802-5 [PMID: 8644926]

MeSH Term

Antibodies, Monoclonal
Antibodies, Monoclonal, Humanized
Chromatography, High Pressure Liquid
Immunoglobulin G
Mass Spectrometry
Molecular Weight
Solvents
Trastuzumab

Chemicals

Antibodies, Monoclonal
Antibodies, Monoclonal, Humanized
Immunoglobulin G
Solvents
Trastuzumab

Word Cloud

Created with Highcharts 10.0.0antibodiesmassmonoclonalusingIT-MScharacterizationintaction-trapon-linereversed-phaseDafirsttime150-kDaMAbscommerciallyavailablethree-dimensionalspectrometerreportedanalysisperformedhighperformanceliquidchromatographyRP-HPLCPOROScolumnnontraditionalsolventsystemacetonitrileisopropanolethanolwaterformicacidoperatingparametersoptimizedextendingrangem/z4000elevatingtubelensoffsetvoltagevaluearound-100VMassaccuracybetter300ppm+/-40routinelyachievedmacromoleculesMultiplepeaks162apartduehexosevariantsIgGpartiallyresolvedspectraSeveralcommercialchimericinvestigatedstudyTrapMAbs:HPLCspectrometry

Similar Articles

Cited By