- Ingrid L Holster: Department of Pediatric Otorhinolaryngology, Sophia Children's Hospital, Rotterdam, The Netherlands. lisanneholster@hotmail.com
OBJECTIVE: We evaluated the causes of hearing loss found after failed universal newborn hearing screening and compared the results with the previously used behavioral observation test (Ewing/CAPAS).
STUDY DESIGN: Hearing loss in neonates, born between September 1999 and October 2007 and referred to our center after failed screening, was determined by audiologic testing and physical examination.
RESULTS: In 340 included neonates the results of hearing tests were as follows: normal hearing 21.2%, conductive hearing loss 20.3%, and sensorineural hearing loss (SNHL) 57.9%. Children referred from the neonatal intensive care unit were more at risk of SNHL (71%) than those from the well-baby clinics (54%). Hearing aids were provided at a median age of 8 months. The positive predictive value of SNHL screening was 54% for a child from a well-baby clinic and 71% for a child from the neonatal intensive care unit.
CONCLUSION: The use of universal newborn hearing screening results in a lower proportion of infants positive because of otitis media with effusion than the previously used Ewing/CAPAS test (20% vs 59-81%). Second, screening leads to identification of hearing loss and intervention at a younger age (8 months vs 15-18 months). Third, the positive predictive value for SNHL has improved (54% vs 2%).