Analysis of pesticide residues by fast gas chromatography in combination with negative chemical ionization mass spectrometry.

Renáta Húsková, Eva Matisová, Svetlana Hrouzková, Lubomír Svorc
Author Information
  1. Renáta Húsková: Institute of Analytical Chemistry, Faculty of Chemical and Food Technology, Slovak University of Technology, Radlinského 9, Bratislava 812 37, Slovak Republic.

Abstract

A combination of fast GC with narrow-bore column and bench top quadrupole mass spectrometer (MS) detector in negative chemical ionization (NCI) mode (with methane as reagent gas) is set up and utilized for the ultratrace analysis of 25 selected pesticides. The observed pesticides, belonging to the endocrine disrupting chemicals (EDCs), were from different chemical classes. A comparative study with electron impact (EI) ionization was also carried out (both techniques in selected ion monitoring (SIM) mode). The programmed temperature vaporizer (PTV) injector in solvent vent mode and narrow-bore column (15mx0.15mm I.D.x0.15microm film of 5% diphenyl 95% dimethylsiloxane stationary phase) were used for effective and fast separation. Heptachlor (HPT) as internal standard (I.S.) was applied for the comparison of results obtained from absolute and normalized peak areas. Non-fatty food matrices were investigated. Fruit (apple - matrix-matched standards; orange, strawberry, plum - real samples) and vegetable (lettuce - real sample) extracts were prepared by a quick and effective QuEChERS sample preparation technique. Very good results were obtained for the characterization of fast GC-NCI-MS method analysing EDCs pesticides. Analyte response was linear from 0.01 to 150microgkg(-1) with the R(2) values in the range from 0.9936 to 1.0000 (calculated from absolute peak areas) and from 0.9956 to 1.0000 (calculated from peak areas normalized to HPT). Instrument limits of detection (LODs) and quantification (LOQs) were found at pgmL(-1) level and for the majority of analytes were up to three orders of magnitude lower for NCI compared to EI mode. In both ionization modes, repeatability of measurements expressed as relative standard deviation (RSDs) was less than 10% which is in very good agreement with the criterion of European Union.

MeSH Term

Aminoimidazole Carboxamide
Endocrine Disruptors
European Union
Food Analysis
Fruit
Gas Chromatography-Mass Spectrometry
Hydantoins
Malathion
Pesticide Residues
Pesticides
Vegetables

Chemicals

Endocrine Disruptors
Hydantoins
Pesticide Residues
Pesticides
Aminoimidazole Carboxamide
iprodione
Malathion

Word Cloud

Created with Highcharts 10.0.0fastionizationmodechemicalpesticidespeakareas-0combinationnarrow-borecolumnmassnegativeNCIgasselectedEDCsEIIeffectiveHPTstandardresultsobtainedabsolutenormalizedrealsamplegood-110000calculatedGCbenchtopquadrupolespectrometerMSdetectormethanereagentsetutilizedultratraceanalysis25observedbelongingendocrinedisruptingchemicalsdifferentclassescomparativestudyelectronimpactalsocarriedtechniquesionmonitoringSIMprogrammedtemperaturevaporizerPTVinjectorsolventvent15mx015mmDx015micromfilm5%diphenyl95%dimethylsiloxanestationaryphaseusedseparationHeptachlorinternalSappliedcomparisonNon-fattyfoodmatricesinvestigatedFruitapplematrix-matchedstandardsorangestrawberryplumsamplesvegetablelettuceextractspreparedquickQuEChERSpreparationtechniquecharacterizationGC-NCI-MSmethodanalysingAnalyteresponselinear01150microgkgR2valuesrange99369956InstrumentlimitsdetectionLODsquantificationLOQsfoundpgmLlevelmajorityanalytesthreeordersmagnitudelowercomparedmodesrepeatabilitymeasurementsexpressedrelativedeviationRSDsless10%agreementcriterionEuropeanUnionAnalysispesticideresidueschromatographyspectrometry

Similar Articles

Cited By (6)