Comparison of separation performance of laser-ablated and wet-etched microfluidic devices.

Christopher A Baker, Rayford Bulloch, Michael G Roper
Author Information
  1. Christopher A Baker: Department of Chemistry and Biochemistry, Florida State University, 95 Chieftain Way, Dittmer Building, Tallahassee, FL 32306, USA.

Abstract

Laser ablation of glass allows for production of microfluidic devices without the need for hydrofluoric acid and photolithography. The goal of this study was to compare the separation performance of microfluidic devices produced using a low-cost laser ablation system and conventional wet etching. During laser ablation, cracking of the glass substrate was prevented by heating the glass to 300 °C. A range of laser energy densities was found to produce channel depths ranging from 4 to 35 μm and channel widths from 118 to 162 μm. The electroosmotic flow velocity was lower in laser-ablated devices, 0.110±0.005 cm s(-1), as compared to wet-etched microfluidic chips, 0.126±0.003 cm s(-1). Separations of both small and large molecules performed on both wet- and laser-ablated devices were compared by examining limits of detection, theoretical plate count, and peak asymmetry. Laser-induced fluorescence detection limits were 10 pM fluorescein for both types of devices. Laser-ablated and wet-etched microfluidic chips had reproducible migration times with ≤ 2.8% relative standard deviation and peak asymmetries ranged from 1.0 to 1.8. Numbers of theoretical plates were between 2.8- and 6.2-fold higher on the wet-etched devices compared to laser-ablated devices. Nevertheless, resolution between small and large analytes was accomplished, which indicates that laser ablation may find an application in pedagogical studies of electrophoresis or microfluidic devices, or in settings where hydrofluoric acid cannot be used.

References

  1. J Am Chem Soc. 2003 Nov 26;125(47):14613-9 [PMID: 14624612]
  2. Electrophoresis. 2003 Nov;24(21):3607-19 [PMID: 14613185]
  3. Anal Chem. 2002 Feb 15;74(4):871-8 [PMID: 11866067]
  4. Analyst. 2009 Jan;134(1):97-106 [PMID: 19082181]
  5. Science. 1998 May 15;280(5366):1046-8 [PMID: 9582111]
  6. J Chromatogr A. 2010 Jul 9;1217(28):4743-8 [PMID: 20730040]
  7. Proc Natl Acad Sci U S A. 2008 Nov 4;105(44):16843-8 [PMID: 18974218]
  8. Science. 2000 Nov 24;290(5496):1536-40 [PMID: 11090344]
  9. Anal Chem. 2010 Mar 15;82(6):2310-6 [PMID: 20151681]
  10. Anal Chem. 2002 Mar 15;74(6):1415-22 [PMID: 11922312]
  11. Opt Lett. 2001 Jan 15;26(2):93-5 [PMID: 18033517]
  12. Anal Chem. 2003 Apr 15;75(8):1880-6 [PMID: 12713046]
  13. Anal Chem. 2001 Jun 1;73(11):2648-55 [PMID: 11403312]
  14. Opt Lett. 2001 Dec 1;26(23):1912-4 [PMID: 18059735]
  15. Lab Chip. 2002 Nov;2(4):242-6 [PMID: 15100818]
  16. Nat Biotechnol. 2001 May;19(5):461-5 [PMID: 11329017]
  17. Anal Chem. 2009 Jun 1;81(11):4524-30 [PMID: 19476392]
  18. Anal Chem. 2006 Feb 1;78(3):956-8 [PMID: 16448074]
  19. Anal Chem. 1998 Dec 1;70(23):4974-84 [PMID: 21644679]
  20. Science. 1993 Aug 13;261(5123):895-7 [PMID: 17783736]
  21. Anal Chem. 2003 Dec 1;75(23):6544-54 [PMID: 14640726]
  22. Analyst. 2006 Feb;131(2):194-201 [PMID: 16440082]
  23. Science. 2002 Oct 18;298(5593):580-4 [PMID: 12351675]
  24. Proc Natl Acad Sci U S A. 2004 Jun 29;101(26):9740-4 [PMID: 15210942]

Grants

  1. R01 DK080714/NIDDK NIH HHS
  2. R01 DK080714-04/NIDDK NIH HHS

MeSH Term

Lasers
Microfluidic Analytical Techniques
Wettability

Word Cloud

Created with Highcharts 10.0.0devicesmicrofluidicablationlaserlaser-ablatedwet-etchedglass0comparedhydrofluoricacidseparationperformancechannelμmcms-1chipssmalllargelimitsdetectiontheoreticalpeak21Laserallowsproductionwithoutneedphotolithographygoalstudycompareproducedusinglow-costsystemconventionalwetetchingcrackingsubstratepreventedheating300°Crangeenergydensitiesfoundproducedepthsranging435widths118162electroosmoticflowvelocitylower110±0005126±0003Separationsmoleculesperformedwet-examiningplatecountasymmetryLaser-inducedfluorescence10pMfluoresceintypesLaser-ablatedreproduciblemigrationtimes8%relativestandarddeviationasymmetriesranged8Numbersplates8-62-foldhigherNeverthelessresolutionanalytesaccomplishedindicatesmayfindapplicationpedagogicalstudieselectrophoresissettingsusedComparison

Similar Articles

Cited By