Dielectric properties of human skin at an acupuncture point in the 50-75 GHz frequency range: a pilot study.

Stéphane J-P Egot-Lemaire, Marvin C Ziskin
Author Information
  1. Stéphane J-P Egot-Lemaire: Center for Biomedical Physics, Temple University Medical School, Philadelphia, PA 19410, USA.

Abstract

The reason for using acupuncture points as exposure sites in some applications of millimeter wave therapy has been unclear. Acupuncture points have been suspected to exhibit particular direct current (DC), low-frequency electrical and optical properties compared to surrounding skin. To assess if such a biophysical correlation could exist at millimeter wave frequencies used in the therapy, we investigated the dielectric properties of an acupuncture point on the forearm skin within the 50-75 GHz range. These properties were compared with those of a neighboring ipsilateral control area and a corresponding contralateral control area. The complex reflection coefficient at the end of an open-ended rectangular waveguide loaded with a Teflon plug was measured with a vector network analyzer. A suitable model of the aperture admittance was used to calculate the dielectric properties of the skin at the measured spots. Statistical analyses were conducted with an ANOVA to compare the three sites. From these analyses, the dielectric properties of the acupuncture site were found to be somewhat different from those of surrounding non-acupuncture sites from 50 to about 61 GHz, in the case of the real part of the complex permittivity.

References

  1. Life Sci. 2001 Jan 26;68(10):1143-51 [PMID: 11228098]
  2. IEEE Trans Biomed Eng. 1975 Nov;22(6):533-5 [PMID: 1184029]
  3. Anat Rec. 2002 Dec 15;269(6):257-65 [PMID: 12467083]
  4. BMC Complement Altern Med. 2005 May 09;5:10 [PMID: 15882468]
  5. Am J Chin Med. 2007;35(5):743-52 [PMID: 17963315]
  6. Acupunct Electrother Res. 2000;25(3-4):165-77 [PMID: 11261767]
  7. Bioelectromagnetics. 2007 Jul;28(5):331-9 [PMID: 17429851]
  8. Brain Res. 2004 Jun 25;1012(1-2):154-9 [PMID: 15158172]
  9. Bioelectromagnetics. 2008 May;29(4):245-56 [PMID: 18240287]
  10. Prog Neurobiol. 2008 Aug;85(4):355-75 [PMID: 18582529]
  11. Evid Based Complement Alternat Med. 2006 Jun;3(2):201-7 [PMID: 16786049]
  12. Bioelectromagnetics. 2008 Jan;29(1):65-70 [PMID: 17929264]
  13. Am J Phys Med Rehabil. 2007 Jan;86(1):7-11 [PMID: 17304683]
  14. QJM. 1998 Jan;91(1):57-66 [PMID: 9519213]
  15. J Invest Dermatol. 1981 Jul;77(1):13-9 [PMID: 7252245]
  16. Am J Chin Med (Gard City N Y). 1976 Spring;4(1):69-72 [PMID: 1266803]
  17. Med Biol. 1977 Apr;55(2):88-94 [PMID: 865155]
  18. FASEB J. 2002 Jun;16(8):872-4 [PMID: 11967233]
  19. Phys Med Biol. 1982 Aug;27(8):1067-71 [PMID: 7122700]
  20. Bioelectromagnetics. 1997;18(4):324-34 [PMID: 9140663]

Grants

  1. P01 AT002025/NCCIH NIH HHS
  2. P01 AT002025-04/NCCIH NIH HHS
  3. P01-AT002025/NCCIH NIH HHS

MeSH Term

Acupuncture Points
Adult
Aged
Electric Capacitance
Electric Impedance
Electricity
Female
Forearm
Galvanic Skin Response
Humans
Male
Middle Aged
Pilot Projects
Skin

Word Cloud

Created with Highcharts 10.0.0propertiesacupunctureskinsitesdielectricpointsmillimeterwavetherapycomparedsurroundingusedpoint50-75 GHzcontrolareacomplexmeasuredanalysesreasonusingexposureapplicationsunclearAcupuncturesuspectedexhibitparticulardirectcurrentDClow-frequencyelectricalopticalassessbiophysicalcorrelationexistfrequenciesinvestigatedforearmwithinrangeneighboringipsilateralcorrespondingcontralateralreflectioncoefficientendopen-endedrectangularwaveguideloadedTeflonplugvectornetworkanalyzersuitablemodelapertureadmittancecalculatespotsStatisticalconductedANOVAcomparethreesitefoundsomewhatdifferentnon-acupuncture5061 GHzcaserealpartpermittivityDielectrichumanfrequencyrange:pilotstudy

Similar Articles

Cited By