Does concrete composition affect photoneutron production inside radiation therapy bunkers?

Asghar Mesbahi, Ali-Asghar Azarpeyvand, Hamid Reza Khosravi
Author Information
  1. Asghar Mesbahi: Medical Physics Department, Medical School, Tabriz University of Medical Sciences, Tabriz, Iran. mesbahiiran@yahoo.com

Abstract

PURPOSE: Different types of concretes are used for bunker construction for radiation therapy. As neutron production occurs in high-energy photon beams, the purpose of this study was to investigate the effect of different concretes on photoneutron doses at an isocenter and maze entrance door.
MATERIALS AND METHODS: The 18-MV photon beam of a Varian 2100 C/D linear accelerator and a radiation therapy bunker were simulated using the MCNPX Monte Carlo code. Different commercially available concretes were used in photoneutron calculations for the simulated bunker.
RESULTS: Higher neutron doses of the water phantom were seen for barytes and galena concretes, while there was no significant (less than 1%) difference between the neutron dose of the phantom for all other concretes. Also, the neutron fluence at the inner and outer maze entrance varied up to 36% depending on the concretes' atomic compositions.
CONCLUSION: It can be concluded that application of high-density concretes in order to use limited space or for other purposes may cause higher neutron doses in the maze entrance door and consequently may impose stricter requirements for neutron shielding of maze entrance doors.

References

  1. Radiat Prot Dosimetry. 2007;123(3):283-7 [PMID: 17005540]
  2. Med Phys. 2008 Jul;35(7):3285-92 [PMID: 18697553]
  3. Radiat Prot Dosimetry. 2006;119(1-4):514-7 [PMID: 16565202]
  4. J Appl Clin Med Phys. 2003 Summer;4(3):189-94 [PMID: 12841788]
  5. Rep Pract Oncol Radiother. 2010 Sep 22;15(5):138-44 [PMID: 24376940]
  6. Med Phys. 1999 Dec;26(12):2520-5 [PMID: 10619233]
  7. Radiat Prot Dosimetry. 2010 Aug;140(3):242-9 [PMID: 20083490]
  8. Radiat Prot Dosimetry. 2007;123(1):56-61 [PMID: 16815885]
  9. Med Phys. 1982 Nov-Dec;9(6):904-6 [PMID: 6819435]

MeSH Term

Computer Simulation
Construction Materials
Health Facilities
Monte Carlo Method
Neutrons
Particle Accelerators
Photons
Radiation Dosage
Radiotherapy, High-Energy

Word Cloud

Created with Highcharts 10.0.0concretesneutronmazeentrancebunkerradiationtherapyphotoneutrondosesDifferentusedproductionphotondoorsimulatedphantommayPURPOSE:typesconstructionoccurshigh-energybeamspurposestudyinvestigateeffectdifferentisocenterMATERIALSANDMETHODS:18-MVbeamVarian2100C/DlinearacceleratorusingMCNPXMonteCarlocodecommerciallyavailablecalculationsRESULTS:Higherwaterseenbarytesgalenasignificantless1%differencedoseAlsofluenceinneroutervaried36%dependingconcretes'atomiccompositionsCONCLUSION:canconcludedapplicationhigh-densityorderuselimitedspacepurposescausehigherconsequentlyimposestricterrequirementsshieldingdoorsconcretecompositionaffectinsidebunkers?

Similar Articles

Cited By (1)