Effect of background correction on peak detection and quantification in online comprehensive two-dimensional liquid chromatography using diode array detection.

Robert C Allen, Mallory G John, Sarah C Rutan, Marcelo R Filgueira, Peter W Carr
Author Information
  1. Robert C Allen: Department of Chemistry, Virginia Commonwealth University, Richmond, VA 23284-2006, USA.

Abstract

A singular value decomposition-based background correction (SVD-BC) technique is proposed for the reduction of background contributions in online comprehensive two-dimensional liquid chromatography (LC×LC) data. The SVD-BC technique was compared to simply subtracting a blank chromatogram from a sample chromatogram and to a previously reported background correction technique for one dimensional chromatography, which uses an asymmetric weighted least squares (AWLS) approach. AWLS was the only background correction technique to completely remove the background artifacts from the samples as evaluated by visual inspection. However, the SVD-BC technique greatly reduced or eliminated the background artifacts as well and preserved the peak intensity better than AWLS. The loss in peak intensity by AWLS resulted in lower peak counts at the detection thresholds established using standards samples. However, the SVD-BC technique was found to introduce noise which led to detection of false peaks at the lower detection thresholds. As a result, the AWLS technique gave more precise peak counts than the SVD-BC technique, particularly at the lower detection thresholds. While the AWLS technique resulted in more consistent percent residual standard deviation values, a statistical improvement in peak quantification after background correction was not found regardless of the background correction technique used.

Grants

  1. GM-54585-13/NIGMS NIH HHS

MeSH Term

Chromatography, Liquid
Least-Squares Analysis
Models, Chemical
Plant Extracts
Reproducibility of Results
Seeds
Sensitivity and Specificity
Zea mays

Chemicals

Plant Extracts

Word Cloud

Created with Highcharts 10.0.0techniquebackgroundcorrectionAWLSpeakdetectionSVD-BCchromatographylowerthresholdsonlinecomprehensivetwo-dimensionalliquidchromatogramartifactssamplesHoweverintensityresultedcountsusingfoundquantificationsingularvaluedecomposition-basedproposedreductioncontributionsLC×LCdatacomparedsimplysubtractingblanksamplepreviouslyreportedonedimensionalusesasymmetricweightedleastsquaresapproachcompletelyremoveevaluatedvisualinspectiongreatlyreducedeliminatedwellpreservedbetterlossestablishedstandardsintroducenoiseledfalsepeaksresultgavepreciseparticularlyconsistentpercentresidualstandarddeviationvaluesstatisticalimprovementregardlessusedEffectdiodearray

Similar Articles

Cited By