Tissue-informative mechanism for wearable non-invasive continuous blood pressure monitoring.

Sung Hun Woo, Yun Young Choi, Dae Jung Kim, Franklin Bien, Jae Joon Kim
Author Information
  1. Sung Hun Woo: UMEDIX Corporation Limited, Seoul, Republic of Korea.
  2. Yun Young Choi: UMEDIX Corporation Limited, Seoul, Republic of Korea.
  3. Dae Jung Kim: UMEDIX Corporation Limited, Seoul, Republic of Korea.
  4. Franklin Bien: School of Electrical and Computer Engineering, Ulsan National Institute of Science and Technology, Ulsan, Republic of Korea.
  5. Jae Joon Kim: School of Electrical and Computer Engineering, Ulsan National Institute of Science and Technology, Ulsan, Republic of Korea.

Abstract

Accurate continuous direct measurement of the blood pressure is currently available thru direct invasive methods via intravascular needles, and is mostly limited to use during surgical procedures or in the intensive care unit (ICU). Non-invasive methods that are mostly based on auscultation or cuff oscillometric principles do provide relatively accurate measurement of blood pressure. However, they mostly involve physical inconveniences such as pressure or stress on the human body. Here, we introduce a new non-invasive mechanism of tissue-informative measurement, where an experimental phenomenon called subcutaneous tissue pressure equilibrium is revealed and related for application in detection of absolute blood pressure. A prototype was experimentally verified to provide an absolute blood pressure measurement by wearing a watch-type measurement module that does not cause any discomfort. This work is supposed to contribute remarkably to the advancement of continuous non-invasive mobile devices for 24-7 daily-life ambulatory blood-pressure monitoring.

References

  1. Blood Press Monit. 2010 Feb;15(1):23-38 [PMID: 20110786]
  2. Technol Health Care. 2002;10(1):65-76 [PMID: 11847449]
  3. J Biomech. 1983;16(2):141-52 [PMID: 6863329]
  4. Eur Heart J. 2007 Jun;28(12):1462-536 [PMID: 17562668]
  5. J Hum Hypertens. 2008 Mar;22(3):220-2 [PMID: 17992251]
  6. Hypertension. 1999 Jan;33(1 Pt 2):212-8 [PMID: 9931107]
  7. Clin Auton Res. 1991 Mar;1(1):43-53 [PMID: 1821665]
  8. Cardiovasc Res. 1998 Jun;38(3):605-16 [PMID: 9747429]
  9. Hypertension. 2005 Jan;45(1):142-61 [PMID: 15611362]
  10. Clin Physiol. 1995 May;15(3):219-29 [PMID: 7621644]
  11. BMJ. 2001 Mar 3;322(7285):531-6 [PMID: 11230071]
  12. Lancet. 1986 Feb 8;1(8476):307-10 [PMID: 2868172]
  13. Anesth Analg. 2005 May;100(5):1289-1294 [PMID: 15845671]
  14. BMJ. 2000 Apr 22;320(7242):1128-34 [PMID: 10775227]
  15. Blood Press Monit. 2002 Feb;7(1):3-17 [PMID: 12040236]
  16. Hypertension. 1997 Apr;29(4):1039-43 [PMID: 9095096]
  17. Anesthesiology. 1999 Sep;91(3):686-92 [PMID: 10485780]
  18. ScientificWorldJournal. 2014 Jan 30;2014:353628 [PMID: 24616624]
  19. J Clin Monit. 1991 Jan;7(1):56-67 [PMID: 1999699]
  20. Med J Aust. 2002 Jun 17;176(12):588-92 [PMID: 12064958]
  21. Physiol Meas. 2003 Aug;24(3):653-60 [PMID: 14509303]

MeSH Term

Blood Pressure
Blood Pressure Monitors
Humans

Word Cloud

Created with Highcharts 10.0.0pressuremeasurementbloodcontinuousmostlynon-invasivedirectmethodsprovidemechanismabsolutemonitoringAccuratecurrentlyavailablethruinvasiveviaintravascularneedleslimitedusesurgicalproceduresintensivecareunitICUNon-invasivebasedauscultationcuffoscillometricprinciplesrelativelyaccurateHoweverinvolvephysicalinconveniencesstresshumanbodyintroducenewtissue-informativeexperimentalphenomenoncalledsubcutaneoustissueequilibriumrevealedrelatedapplicationdetectionprototypeexperimentallyverifiedwearingwatch-typemodulecausediscomfortworksupposedcontributeremarkablyadvancementmobiledevices24-7daily-lifeambulatoryblood-pressureTissue-informativewearable

Similar Articles

Cited By