Smart Sensing System for the Prognostic Monitoring of Bone Health.

Nasrin Afsarimanesh, Asif I Zia, Subhas Chandra Mukhopadhyay, Marlena Kruger, Pak-Lam Yu, Jurgen Kosel, Zoltan Kovacs
Author Information
  1. Nasrin Afsarimanesh: School of Engineering and Advanced Technology, Massey University, Palmerston North 4442, New Zealand. afsarimanesh@yahoo.com.
  2. Asif I Zia: School of Engineering and Advanced Technology, Massey University, Palmerston North 4442, New Zealand. a.i.zia@me.com.
  3. Subhas Chandra Mukhopadhyay: Department of Engineering, Macquarie University, North Ryde NSW 2109, Australia. subhas.mukhopadhyay@mq.edu.au.
  4. Marlena Kruger: Institute of Food Science and Technology, Massey University, Palmerston North 4442, New Zealand. M.C.Kruger@massey.ac.nz.
  5. Pak-Lam Yu: School of Engineering and Advanced Technology, Massey University, Palmerston North 4442, New Zealand. P.Yu@massey.ac.nz.
  6. Jurgen Kosel: Sensing, Magnetism and Microsystems Group, King Abdullah University of Science and Technology, Thuwal 23955-6900, Saudi Arabia. jurgen.kosel@kaust.edu.sa.
  7. Zoltan Kovacs: Department of Physics and Control, Faculty of Food Science, Szent István University, Budapest H-1118, Hungary. zoltan.kovacs@chemometrics.hu.

Abstract

The objective of this paper is to report a novel non-invasive, real-time, and label-free smart assay technique for the prognostic detection of bone loss by electrochemical impedance spectroscopy (EIS). The proposed system incorporated an antibody-antigen-based sensor functionalization to induce selectivity for the C-terminal telopeptide type one collagen (CTx-I) molecules-a bone loss biomarker. Streptavidin agarose was immobilized on the sensing area of a silicon substrate-based planar sensor, patterned with gold interdigital electrodes, to capture the antibody-antigen complex. Calibration experiments were conducted with various known CTx-I concentrations in a buffer solution to obtain a reference curve that was used to quantify the concentration of an analyte in the unknown serum samples. Multivariate chemometric analyses were done to determine the performance viability of the developed system. The analyses suggested that a frequency of 710 Hz is the most discriminating regarding the system sensitivity. A detection limit of 0.147 ng/mL was achieved for the proposed sensor and the corresponding reference curve was linear in the range of 0.147 ng/mL to 2.669 ng/mL. Two sheep blood samples were tested by the developed technique and the results were validated using enzyme-linked immunosorbent assay (ELISA). The results from the proposed technique match those from the ELISA.

Keywords

References

  1. Osteoporos Int. 2008 Dec;19(12):1683-704 [PMID: 18629570]
  2. Small. 2010 Jan;6(2):232-8 [PMID: 19882688]
  3. Osteoporos Int. 2000;11(8):669-74 [PMID: 11095169]
  4. J Bone Miner Res. 2005 May;20(5):886-92 [PMID: 15931736]
  5. Clin Biochem. 1997 Dec;30(8):573-93 [PMID: 9455610]
  6. Sensors (Basel). 2009;9(10):7957-69 [PMID: 22408488]
  7. Biosens Bioelectron. 2016 Mar 15;77:580-8 [PMID: 26476598]
  8. J Obstet Gynaecol Can. 2014 Sep;36(9):839-840 [PMID: 25222365]
  9. CMAJ. 2010 Nov 23;182(17):1864-73 [PMID: 20940232]
  10. Food Chem. 2015 Jun 1;176:22-6 [PMID: 25624202]
  11. Biosens Bioelectron. 2013 Feb 15;40(1):422-6 [PMID: 22917917]
  12. Sensors (Basel). 2013 Apr 11;13(4):4811-40 [PMID: 23580051]
  13. Biosens Bioelectron. 2015 Mar 15;65:314-9 [PMID: 25461175]
  14. Calcif Tissue Int. 2001 Dec;69(6):327-36 [PMID: 11800229]
  15. Biosens Bioelectron. 2013 Feb 15;40(1):258-64 [PMID: 22883747]
  16. J Invest Dermatol. 2013 Sep;133(9):e12 [PMID: 23949770]
  17. Biosens Bioelectron. 2015 May 15;67:342-9 [PMID: 25218198]
  18. Biosens Bioelectron. 2013 May 15;43:79-83 [PMID: 23287651]

MeSH Term

Animals
Biosensing Techniques
Bone and Bones
Calibration
Collagen Type I
Electric Impedance
Equipment Design
Least-Squares Analysis
Monitoring, Physiologic
Multivariate Analysis
Nonlinear Dynamics
Peptides
Principal Component Analysis
Prognosis
Reference Standards
Sheep
Statistics as Topic

Chemicals

Collagen Type I
Peptides
collagen type I trimeric cross-linked peptide

Word Cloud

Created with Highcharts 10.0.0techniqueboneproposedsystemsensorng/mLELISAassaydetectionlossEISCTx-Iinterdigitalreferencecurvesamplesanalysesdeveloped0147resultsobjectivepaperreportnovelnon-invasivereal-timelabel-freesmartprognosticelectrochemicalimpedancespectroscopyincorporatedantibody-antigen-basedfunctionalizationinduceselectivityC-terminaltelopeptidetypeonecollagenmolecules-abiomarkerStreptavidinagaroseimmobilizedsensingareasiliconsubstrate-basedplanarpatternedgoldelectrodescaptureantibody-antigencomplexCalibrationexperimentsconductedvariousknownconcentrationsbuffersolutionobtainusedquantifyconcentrationanalyteunknownserumMultivariatechemometricdonedetermineperformanceviabilitysuggestedfrequency710Hzdiscriminatingregardingsensitivitylimitachievedcorrespondinglinearrange2669Twosheepbloodtestedvalidatedusingenzyme-linkedimmunosorbentmatchSmartSensingSystemPrognosticMonitoringBoneHealthElectrochemicalImpedanceSpectroscopyEnzyme-LinkedImmunosorbentAssayturnovermarkerssensors

Similar Articles

Cited By