Voltammetric Detection of Urea on an Ag-Modified Zeolite-Expanded Graphite-Epoxy Composite Electrode.

Florica Manea, Aniela Pop, Ciprian Radovan, Plamen Malchev, Adriana Bebeselea, Georgeta Burtica, Stephen Picken, Joop Schoonman
Author Information
  1. Florica Manea: "Politehnica" University of Timisoara, P-ta Victoriei, nr.2, 300006, Timisoara, Romania. florica.manea@chim.upt.ro.
  2. Aniela Pop: "Politehnica" University of Timisoara, P-ta Victoriei, nr.2, 300006, Timisoara, Romania. aniela.pop@chim.upt.ro.
  3. Ciprian Radovan: West University of Timisoara, Laboratory of Electrochemistry, Str. Pestalozzi nr.16, 300115 Timisoara, Romania. radovan@cbg.uvt.ro.
  4. Plamen Malchev: Delft University of Technology, 2600 GA Delft, The Netherlands. p.g.malchev@tudelft.nl.
  5. Adriana Bebeselea: "Politehnica" University of Timisoara, P-ta Victoriei, nr.2, 300006, Timisoara, Romania. adriana.bebeselea@chim.upt.ro.
  6. Georgeta Burtica: "Politehnica" University of Timisoara, P-ta Victoriei, nr.2, 300006, Timisoara, Romania. georgeta.burtica@chim.upt.ro.
  7. Stephen Picken: Delft University of Technology, 2600 GA Delft, The Netherlands. s.j.picken@tudelft.nl.
  8. Joop Schoonman: Delft University of Technology, 2600 GA Delft, The Netherlands. j.schoonman@tudelft.nl.

Abstract

In this paper, a modified expanded graphite composite electrode based on natural zeolitic volcanic tuff modified with silver (EG-Ag-Z-Epoxy) was developed. Cyclic voltammetry measurements revealed a reasonably fast electron transfer and a good stability of the electrode in 0.1 M NaOH supporting electrolyte. This modified electrode exhibited moderate electrocatalytic effect towards urea oxidation, allowing its determination in aqueous solution. The linear dependence of the current versus urea concentration was reached using square-wave voltammetry in the concentrations range of urea between 0.2 to 1.4 mM, with a relatively low limit of detection of 0.05 mM. A moderate enhancement of electroanalytical sensitivity for the determination of urea at EG-Ag-Z-Epoxy electrode was reached by applying a chemical preconcentration step prior to voltammetric/amperometric quantification.

Keywords

References

  1. Biosens Bioelectron. 1999 Jan 1;14(1):33-41 [PMID: 10028647]
  2. Water Sci Technol. 2002;46(6-7):341-6 [PMID: 12381010]
  3. Nephrol Dial Transplant. 2004 Jun;19(6):1533-41 [PMID: 15069181]
  4. Anal Sci. 2006 Jan;22(1):173-6 [PMID: 16429798]

Word Cloud

Created with Highcharts 10.0.0electrodeureamodified0determinationexpandedcompositeEG-Ag-Z-Epoxyvoltammetry1moderateelectrocatalyticeffectreachedmMUreapapergraphitebasednaturalzeoliticvolcanictuffsilverdevelopedCyclicmeasurementsrevealedreasonablyfastelectrontransfergoodstabilityMNaOHsupportingelectrolyteexhibitedtowardsoxidationallowingaqueoussolutionlineardependencecurrentversusconcentrationusingsquare-waveconcentrationsrange24relativelylowlimitdetection05enhancementelectroanalyticalsensitivityapplyingchemicalpreconcentrationsteppriorvoltammetric/amperometricquantificationVoltammetricDetectionAg-ModifiedZeolite-ExpandedGraphite-EpoxyCompositeElectrodegraphite-Ag-zeolite-epoxy

Similar Articles

Cited By (4)