Diffusion-Weighted Imaging of the Head and Neck: Influence of Fat-Suppression Technique and Multishot 2D Navigated Interleaved Acquisitions.

Y J Bae, B S Choi, H-K Jeong, L Sunwoo, C Jung, J H Kim
Author Information
  1. Y J Bae: From the Department of Radiology (Y.J.B., B.S.C., L.S., C.J., J.H.K.), Seoul National University Bundang Hospital, Seongnam, Republic of Korea. ORCID
  2. B S Choi: From the Department of Radiology (Y.J.B., B.S.C., L.S., C.J., J.H.K.), Seoul National University Bundang Hospital, Seongnam, Republic of Korea byungse.choi@gmail.com. ORCID
  3. H-K Jeong: Philips Korea (H.-K.J.), Seoul, Republic of Korea. ORCID
  4. L Sunwoo: From the Department of Radiology (Y.J.B., B.S.C., L.S., C.J., J.H.K.), Seoul National University Bundang Hospital, Seongnam, Republic of Korea. ORCID
  5. C Jung: From the Department of Radiology (Y.J.B., B.S.C., L.S., C.J., J.H.K.), Seoul National University Bundang Hospital, Seongnam, Republic of Korea. ORCID
  6. J H Kim: From the Department of Radiology (Y.J.B., B.S.C., L.S., C.J., J.H.K.), Seoul National University Bundang Hospital, Seongnam, Republic of Korea. ORCID

Abstract

BACKGROUND AND PURPOSE: DWI of the head and neck can reveal valuable information, but the effects of fat suppression and multishot acquisition on image quality have not been thoroughly investigated. We aimed to comprehensively compare the quality of head and neck DWI at 3T using 2 fat-suppression techniques, STIR, and spectral presaturation with inversion recovery, which were used with both single- and multishot EPI.
MATERIALS AND METHODS: Sixty-five study participants underwent 3 DWI sequences of single-shot EPI-STIR, single-shot EPI-spectral presaturation with inversion recovery, and multishot EPI-spectral presaturation with inversion recovery of the head and neck. In multiple anatomic regions, 2 independent readers assessed 5-point visual scores for fat-suppression uniformity and image distortion, and 1 reader measured the contrast-to-noise ratio and ADC.
RESULTS: The mean visual score for fat-suppression uniformity was higher in single-shot EPI-STIR than in other sequences (all regions except for the orbital region, < .05). The mean visual score for image distortion was higher in multishot EPI-spectral presaturation with inversion recovery than in single-shot EPI sequences (all regions, < .001). Contrast-to-noise ratio was mostly lower in single-shot EPI-STIR than in other sequences ( < .001), and ADC was significantly higher in multishot EPI-spectral presaturation with inversion recovery than in single-shot EPI sequences ( ≤ .001).
CONCLUSIONS: Overall, multishot EPI-spectral presaturation with inversion recovery provided the best image quality, with relatively homogeneous fat suppression, less image distortion than single-shot EPI sequences, and higher contrast-to-noise ratio than single-shot EPI-STIR. The measured ADC values can be higher in multishot EPI-spectral presaturation with inversion recovery, which necessitates cautious application of the previously reported ADC values to clinical settings.

References

  1. Jpn J Radiol. 2009 May;27(4):163-7 [PMID: 19499306]
  2. Eur Radiol. 2014 Dec;24(12):3088-96 [PMID: 25117744]
  3. Radiol Med. 2015 Aug;120(8):705-13 [PMID: 25665796]
  4. Radiographics. 2011 Jul-Aug;31(4):1059-84 [PMID: 21768239]
  5. Acad Radiol. 2007 Sep;14(9):1077-83 [PMID: 17707315]
  6. Radiology. 2012 Apr;263(1):19-32 [PMID: 22438440]
  7. Magn Reson Med. 2009 Aug;62(2):468-75 [PMID: 19449372]
  8. Magn Reson Imaging. 2016 Feb;34(2):166-72 [PMID: 26541548]
  9. Magn Reson Med. 2015 Oct;74(4):953-63 [PMID: 25263603]
  10. Eur J Radiol. 2003 Mar;45(3):208-13 [PMID: 12595105]
  11. Invest Radiol. 2006 Oct;41(10):769-75 [PMID: 16971801]
  12. Eur J Radiol. 2007 May;62(2):205-13 [PMID: 17188444]
  13. Magn Reson Med. 2004 May;51(5):1048-54 [PMID: 15122689]
  14. Radiology. 1988 Aug;168(2):497-505 [PMID: 3393671]
  15. NMR Biomed. 2010 May;23(4):399-405 [PMID: 20131313]
  16. AJNR Am J Neuroradiol. 2007 Jun-Jul;28(6):1146-52 [PMID: 17569975]
  17. Magn Reson Med. 2013 Mar 1;69(3):793-802 [PMID: 22592941]
  18. Eur Radiol. 2014 Oct;24(10):2540-51 [PMID: 24898097]
  19. Magn Reson Imaging. 2014 Jun;32(5):440-5 [PMID: 24582547]
  20. AJNR Am J Neuroradiol. 2008 Jan;29(1):40-4 [PMID: 17921228]
  21. Radiology. 2009 Apr;251(1):134-46 [PMID: 19251938]
  22. J Magn Reson Imaging. 2000 Jan;11(1):56-60 [PMID: 10676621]

MeSH Term

Adult
Aged
Aged, 80 and over
Diffusion Magnetic Resonance Imaging
Echo-Planar Imaging
Female
Head
Humans
Image Interpretation, Computer-Assisted
Male
Middle Aged
Neck
Reproducibility of Results
Retrospective Studies

Word Cloud

Created with Highcharts 10.0.0single-shotmultishotpresaturationinversionrecoverysequencesEPI-spectralimagehigherEPIEPI-STIRADCDWIheadneckqualityfat-suppressionregionsvisualdistortionratio<001ANDcanfatsuppression2uniformitymeasuredcontrast-to-noisemeanscorevaluesBACKGROUNDPURPOSE:revealvaluableinformationeffectsacquisitionthoroughlyinvestigatedaimedcomprehensivelycompare3TusingtechniquesSTIRspectralusedsingle-MATERIALSMETHODS:Sixty-fivestudyparticipantsunderwent3multipleanatomicindependentreadersassessed5-pointscores1readerRESULTS:exceptorbitalregion05Contrast-to-noisemostlylowersignificantlyCONCLUSIONS:OverallprovidedbestrelativelyhomogeneouslessnecessitatescautiousapplicationpreviouslyreportedclinicalsettingsDiffusion-WeightedImagingHeadNeck:InfluenceFat-SuppressionTechniqueMultishot2DNavigatedInterleavedAcquisitions

Similar Articles

Cited By