Carbon Nanotube Strain Sensor Based Hemoretractometer for Blood Coagulation Testing.

Zida Li, Yize Wang, Xufeng Xue, Brendan McCracken, Kevin Ward, Jianping Fu
Author Information

Abstract

Coagulation monitoring is essential for perioperative care and thrombosis treatment. However, existing assays for coagulation monitoring have limitations such as a large footprint and complex setup. In this work, we developed a miniaturized device for point-of-care blood coagulation testing by measuring dynamic clot retraction force development during blood clotting. In this device, a blood drop was localized between a protrusion and a flexible force-sensing beam to measure clot retraction force. The beam was featured with micropillar arrays to assist the deposition of carbon nanotube films, which served as a strain sensor to achieve label-free electrical readout of clot retraction force in real time. We characterized mechanical and electrical properties of the force-sensing beam and optimized its design. We further demonstrated that this blood coagulation monitoring device could obtain results that were consistent with those using an imaging method and that the device was capable of differentiating blood samples with different coagulation profiles. Owing to its low fabrication cost, small size, and low consumption of blood samples, the blood coagulation testing device using carbon nanotube strain sensors holds great potential as a point-of-care tool for future coagulation monitoring.

Keywords

References

  1. Thromb Res. 2002 Nov 1;108(2-3):161-8 [PMID: 12590953]
  2. IEEE Trans Biomed Circuits Syst. 2017 Dec;11(6):1459-1469 [PMID: 28920906]
  3. Biosens Bioelectron. 2005 Mar 15;20(9):1737-43 [PMID: 15681188]
  4. Thromb Haemost. 1996 Apr;75(4):674-8 [PMID: 8743198]
  5. Appl Phys Lett. 2017 Oct 23;111(17):173105 [PMID: 30405247]
  6. Anesth Analg. 2009 May;108(5):1433-46 [PMID: 19372317]
  7. Nat Mater. 2011 Jan;10(1):61-6 [PMID: 21131961]
  8. Br J Anaesth. 2004 Dec;93(6):842-58 [PMID: 15277296]
  9. J Biol Chem. 2001 May 4;276(18):14961-71 [PMID: 11278930]
  10. Trends Biotechnol. 2014 Nov;32(11):586-594 [PMID: 25283971]
  11. Lab Chip. 2011 Mar 7;11(5):962-5 [PMID: 21152492]
  12. Anesthesiology. 2011 Dec;115(6):1179-91 [PMID: 21970887]
  13. Anesth Analg. 2008 May;106(5):1366-75 [PMID: 18420846]
  14. Clin Chim Acta. 2010 Jan;411(1-2):106-13 [PMID: 19861121]
  15. Lab Chip. 2010 Apr 21;10(8):991-8 [PMID: 20358105]
  16. Anal Chem. 2010 Jan 15;82(2):658-63 [PMID: 20000697]
  17. J Cell Sci. 2012 Aug 15;125(Pt 16):3914-20 [PMID: 22582082]
  18. Small. 2016 Aug;12(29):3926-34 [PMID: 27248117]
  19. Nat Mater. 2017 Feb;16(2):230-235 [PMID: 27723740]
  20. Biomed Opt Express. 2014 Feb 24;5(3):817-31 [PMID: 24688816]
  21. Lab Chip. 2015 Jan 7;15(1):113-20 [PMID: 25353144]

Grants

  1. R01 HL119542/NHLBI NIH HHS

MeSH Term

Blood Coagulation
Blood Coagulation Tests
Equipment Design
Humans
Nanotubes, Carbon
Point-of-Care Systems

Chemicals

Nanotubes, Carbon

Word Cloud

Created with Highcharts 10.0.0bloodcoagulationdevicemonitoringclotretractionforcepoint-of-carebeamcarbonnanotubestrainCoagulationtestingforce-sensingsensorelectricalusingsampleslowessentialperioperativecarethrombosistreatmentHoweverexistingassayslimitationslargefootprintcomplexsetupworkdevelopedminiaturizedmeasuringdynamicdevelopmentclottingdroplocalizedprotrusionflexiblemeasurefeaturedmicropillararraysassistdepositionfilmsservedachievelabel-freereadoutrealtimecharacterizedmechanicalpropertiesoptimizeddesigndemonstratedobtainresultsconsistentimagingmethodcapabledifferentiatingdifferentprofilesOwingfabricationcostsmallsizeconsumptionsensorsholdsgreatpotentialtoolfutureCarbonNanotubeStrainSensorBasedHemoretractometerBloodTestingdiagnostics

Similar Articles

Cited By