Surgeon-stratified cohort analysis of 1976 cementless Zweymüller total hip arthroplasties from a single hospital with 23,255 component years of follow-up.

Samo Roškar, Vane Antolič, Blaž Mavčič
Author Information
  1. Samo Roškar: Faculty of Medicine, University of Ljubljana, Zaloška 9, 1000, Ljubljana, Slovenia.
  2. Vane Antolič: Faculty of Medicine, University of Ljubljana, Zaloška 9, 1000, Ljubljana, Slovenia.
  3. Blaž Mavčič: Faculty of Medicine, University of Ljubljana, Zaloška 9, 1000, Ljubljana, Slovenia. blaz.mavcic@kclj.si. ORCID

Abstract

INTRODUCTION: The third-generation Zweymüller hip endoprosthesis has been used for decades with excellent results in arthroplasty registries, but surgeon-stratified reports on this implant are still scarce. The aim of the presented single-hospital cohort analysis of the third-generation Endoplus-Zweymüller primary total hip arthroplasty was to determine implant survival rates until the first revision/removal at 10/15/20/25 years after implantation and to find out whether implant survival depended on the operating surgeon, patient's age and gender, operated side (right/left), season of the year and the set of implanted components (SL-PLUS femur, BICON-PLUS acetabulum or both components).
MATERIALS AND METHODS: The retrospective observational cohort study included 1976 consecutive patients with primary BICON/SL-PLUS Zweymüller hip endoprosthesis implanted at the same operating theater block of the University Medical Centre Ljubljana, Department of Orthopaedic Surgery (Ljubljana, Slovenia) between January 1, 1993 and May 1, 2014. Survival analyses were performed with the Kaplan-Meier method and the Cox regression analysis after minimum 5 and maximum 26 years of follow-up.
RESULTS: At 10/15/20/25 years after implantation, the cumulative proportion of revision-free surviving Zweymüller total hip endoprostheses was 92/90/85/81% and the cumulative proportion with unremoved immobile components was 93/91/87/84%, respectively. After adjustment for age, gender and operated side, less experienced surgeons (odds ratios 2.34-5.00), season of the year at primary implantation (spring vs. winter odds ratio 1.74) and the use of BICON-PLUS acetabulum with femoral stem from another manufacturer (odds ratio 2.23) were significant risk factors of worse implant survival.
CONCLUSIONS: The study presents the largest published third-generation Zweymüller BICON/SL-PLUS total hip arthroplasty cohort from a single non-developmental hospital with 23,255 component years of observation. Study findings indicate the impact of environmental factors at primary implantation and variability between different surgeons on the long-term implant survival.

Keywords

References

  1. Zweymüller K, Litner F, Böhm G (1995) The development of the cementless hip endoprothesis: 1979–1994. In: Morscher EW (ed) Endoprosthetics. Springer, Berlin, pp 309–325 [DOI: 10.1007/978-3-642-79306-6_22]
  2. Wright C, Lambert D, Brazil D, Keggi K, Keggi J, McTighe T (2011) Clinical review of the Zweymuller femoral stem. Reconstr Rev 1(1):41–52
  3. van Oldenrijk J, Scholtes VAB, van Beers LWAH, Geerdink CH, Niers BBAM, Runne W, Bhandari M, Poolman RW, CUSTOM trail research collaborative (2017) Better early functional outcome after short stem total hip arthroplasty? A prospective blinded randomised multicentre trial comparing the collum femoris preserving stem with a Zweymuller straight cementless stem total hip replacement for the treatment of primary osteoarthritis of the hip. BMJ Open 7(10):e014522 [DOI: 10.1136/bmjopen-2016-014522]
  4. Schmolders J, Amvrazis G, Pennekamp PH, Strauss AC, Fridrich MJ, Wimmer MD, Rommelspracher Y, Wirtz DC, Allny T (2017) Thirteen year follow-up of a cementless femoral stem and a threaded acetabular cup in patients younger than fifty years of age. Int Orthop 41(1):39–45 [DOI: 10.1007/s00264-016-3226-z]
  5. Studers P, Belajevs D, Jurkevics V, Likums P (2016) Ten to fifteen-year clinical and radiographic follow-up with a third-generation cementless stem in a young patient population. Int Orthop 40(3):465–471 [DOI: 10.1007/s00264-015-2846-z]
  6. Milošev I, Kovač S, Trebše R, Levašič V, Pišot V (2012) Comparison of ten-year survivorship of hip prostheses with use of conventional polyethylene, metal-on-metal, or ceramic-on-ceramic bearings. J Bone Jt Surg Am 94(19):1756–1763 [DOI: 10.2106/JBJS.J.01858]
  7. Vogel D, Rathay A, Teufel S, Ellenrieder M, Zietz C, Sander M, Bader R (2017) Experimental analysis of insertion torques and forces of threaded and press-fit acetabular cups by means of ex vivo and in vivo measurements. Acta Bioeng Biomech 19(3):155–163 [PMID: 29205219]
  8. Ottink K, Barnaart L, Westerbeck R, van Kampen K, Bulstra S, van Jonbergen HP (2015) Survival, clinical and radiological outcome of the Zweymüller SL/Bicon-Plus total hip arthroplasty: a 15-year follow-up study. Hip Int 25(3):204–208 [DOI: 10.5301/hipint.5000231]
  9. Gielis WP, van Oldenrijk J, Ten Cate N, Scholtes VAB, Geerdink CH, Poolman RW (2019) Increased persistent mid-thigh pain after short-stem compared with wedge-shaped straight-stem uncemented total hip arthroplasty at medium-term follow-up: a randomized double-blinded cross-sectional study. J Arthroplasty 35(5):912–919 [DOI: 10.1016/j.arth.2019.01.014]
  10. Busch VJ, Pouw MH, Laumen AM, van Susante JL, Vervest AM (2012) Long-term outcome of 73 Zweymüller total hip prostheses with a screw cup in patients under 50 years of age. Hip Int 22(3):292–295 [DOI: 10.5301/HIP.2012.9239]
  11. Veen EJD, Schrier JCM, van’t Reit E (2016) Outcome of the cementless Zweymüller BICON-PLUS cup and SL-PLUS stem in the very elderly individuals. Geriatr Orthop Surg Rehabil 7(2):74–80 [DOI: 10.1177/2151458516638902]
  12. Kolb A, Grübl A, Schneckener CD, Chiari C, Kaider A, Lass R, Windhager R (2012) Cementless total hip arthroplasty with rectangular Zweymüller stem: a concise follow-up, at a minimum of twenty years, of previous reports. J Bone Jt Surg Am 94(18):1681–1684 [DOI: 10.2106/JBJS.K.01574]
  13. Weissinger M, Helmreich C, Pöll G (2010) Results covering 20 years use of the cement-free Zweymüller Alloclassic total endoprosthesis of the hip joint. Acta Chir Orthop Traumatol Cech 77(3):186–193 [PMID: 20619109]
  14. Labek G, Kovač S, Levašič V, Janda W, Zagra L (2012) The outcome of the cementless tapered SL-Plus stem: an analysis of arthroplasty register data. Int Orthop 36(6):1149–1154 [DOI: 10.1007/s00264-011-1421-5]
  15. Labek G, Thaler M, Janda W, Argeiter M, Stöckl B (2011) Revisions rates after total joint replacement: cumulative results from worldwide joint register datasets. J Bone Jt Surg Br 93(3):293–297 [DOI: 10.1302/0301-620X.93B3.25467]
  16. Toossi N, Adeli B, Timperley AJ, Haddad FS, Maltenfort M, Parvizi J (2013) Acetabular components in total hip arthroplasty: is there evidence that cementless fixation is better? J Bone Jt Surg Am 95(2):168–174 [DOI: 10.2106/JBJS.K.01652]
  17. Pieringer H, Auersperg V, Böhler N (2006) Long-term results of the cementless Alloclassic hip arthroplasty system using a 28-mm ceramic head: with retrospective comparison to a 32-mm head. J Arthroplasty 21(7):967–974 [DOI: 10.1016/j.arth.2005.08.027]
  18. Valdoltra Orthopaedic Hospital (2019) The National Arthroplasty Registry of Slovenia Ankaran: Ortopedska bolnišnica Valdoltra. https://www.ob-valdoltra.si/sl/international . Accessed 19 Dec 2019
  19. Cruz-Pardos A, García-Rey E, García-Cimbrelo E (2017) Total hip arthroplasty with use of the cementless Zweymüller alloclassic system: a concise follow-up, at a minimum of 25 years, of a previous report. J Bone Jt Surg Am 99(22):1927–1931 [DOI: 10.2106/JBJS.16.01109]
  20. Pisecky L, Hipmair G, Schauer B, Böhler N (2019) 30-Years of experience with the cementless implanted Alloclassic CSF screw cup total hip arthroplasty system—an ultra-long-term follow-up. J Orthop 16(2):182–186 [DOI: 10.1016/j.jor.2019.02.019]
  21. Makarewich CA, Anderson MB, Gililland JM, Pelt CE, Peters CL (2018) Ten-year survivorship of primary total hip arthroplasty in patients 30 years of age or younger. Bone Jt J 100(7):867–874 [DOI: 10.1302/0301-620X.100B7.BJJ-2017-1603.R1]
  22. Parkinson B, Armit D, McEwen P, Lorimer M, Harris IA (2018) Is climate associated with revision for prosthetic joint infection after primary TKA? Clin Orthop Relat Res 476(6):1200–1204 [DOI: 10.1007/s11999.0000000000000144]
  23. Kane P, Chen C, Post Z, Radcliff K, Orozco F, Ong A (2014) Seasonality of infection rates after total joint arthroplasty. Orthopedics 37(2):e182–e186 [DOI: 10.3928/01477447-20140124-23]
  24. Malik AT, Azmat SK, Ali A et al (2018) Seasonal influence on postoperative complications after total knee arthroplasty. Knee Surg Relat Res 30(1):42–49 [DOI: 10.5792/ksrr.17.052]
  25. Hasegawa Y, Amano T (2015) Surgical skills training for primary total hip arthroplasty. Nagoya J Med Sci 77(1–2):51–57 [PMID: 25797970]
  26. Wilson MD, Dowsey MM, Spelman T, Choong PF (2016) Impact of surgical experience on outcomes in total joint arthroplasties. ANZ J Surg 86(12):967–972 [DOI: 10.1111/ans.13513]
  27. Jolbäck P, Rolfson O, Mohaddes M, Nemes S, Kärrholm J, Garellick G, Lindahl H (2018) Does surgeon experience affect patient-reported outcomes 1 year after primary total hip arthroplasty? Acta Orthop 89(3):265–271 [DOI: 10.1080/17453674.2018.1444300]
  28. Cossec CL, Colas S, Zureik M (2017) Relative impact of hospital and surgeon procedure volumes on primary total hip arthroplasty revision: a nationwide cohort study in France. Arthroplast Today 3(3):176–182 [DOI: 10.1016/j.artd.2017.03.010]
  29. Bohl DD, Nolte MT, Ong K, Lau E, Calkins TE, Della Valle CJ (2019) Computer-assisted navigation is associated with reductions in the rates of dislocation and acetabular component revision following primary total hip arthroplasty. J Bone Jt Surg Am 101(3):250–256 [DOI: 10.2106/JBJS.18.00108]

MeSH Term

Arthroplasty, Replacement, Hip
Follow-Up Studies
Hip Joint
Hip Prosthesis
Humans
Prosthesis Design
Reoperation
Retrospective Studies

Word Cloud

Created with Highcharts 10.0.0hipZweymüllerimplantarthroplastycohortprimarytotalsurvivalimplantationthird-generationanalysiscomponents1odds23endoprosthesis10/15/20/25 yearsoperatingagegenderoperatedsideseasonyearimplantedBICON-PLUSacetabulumstudy1976BICON/SL-PLUSLjubljanaSurvivalfollow-upcumulativeproportionsurgeons2ratiofactorssinglehospital255componentyearsSurgeon-stratifiedINTRODUCTION:useddecadesexcellentresultsregistriessurgeon-stratifiedreportsstillscarceaimpresentedsingle-hospitalEndoplus-Zweymüllerdetermineratesfirstrevision/removalfindwhetherdependedsurgeonpatient'sright/leftsetSL-PLUSfemurMATERIALSANDMETHODS:retrospectiveobservationalincludedconsecutivepatientstheaterblockUniversityMedicalCentreDepartmentOrthopaedicSurgerySloveniaJanuary1993May2014analysesperformedKaplan-MeiermethodCoxregressionminimum5maximum26 yearsRESULTS:revision-freesurvivingendoprostheses92/90/85/81%unremovedimmobile93/91/87/84%respectivelyadjustmentlessexperiencedratios34-500springvswinter74usefemoralstemanothermanufacturersignificantriskworseCONCLUSIONS:presentslargestpublishednon-developmentalobservationStudyfindingsindicateimpactenvironmentalvariabilitydifferentlong-termcementlessarthroplastiesCohortTotal