Isabella Barros Almeida, Luciana Garcez Barretto Teixeira, Fernanda Oliveira de Carvalho, Érika Ramos Silva, Paula Santos Nunes, Márcio Roberto Viana Dos Santos, Adriano Antunes de Souza Araújo
Author Information
Isabella Barros Almeida: At the Federal University of Sergipe, Sanatório, Aracaju, Brazil, Isabella Barros Almeida, PhD, is a physician; Luciana Garcez Barretto Teixeira, MS, is a doctoral student; Fernanda Oliveira de Carvalho, PhD, is a physiotherapist; Érika Ramos Silva, PhD, is Professor, Department of Physiotherapy; Paula Santos Nunes, PhD, is Professor, Department of Morphology; Márcio Roberto Viana dos Santos, PhD, is Professor, Department of Morphology; and Adriano Antunes de Souza Araújo, PhD, is Professor, Department of Pharmacy. The authors have disclosed no financial relationships related to this article. Submitted July 19, 2020; accepted in revised form September 25, 2020.
OBJECTIVE: To provide an overview of sensors incorporated into wound dressings that can be used to assess and manage healing parameters. DATA SOURCES: Authors conducted an extensive literature search of the Science Direct, Scopus, MEDLINE-PubMed, and Web of Science databases. STUDY SELECTION: A total of 587 studies that evaluated dressings used to manage wound healing parameters were identified in the search, but only 16 met all of the review criteria and were included in the final analysis. DATA EXTRACTION: Chronic wounds were the most common type of injury among studies. Six articles involved a wireless transmission system. DATA SYNTHESIS: All studies evaluated the physical and chemical characteristics of the dressings. CONCLUSIONS: This review demonstrates the lack of studies examining wound dressing sensors. New studies are required to assess sensors that allow not only wound monitoring, but also the application of drugs in a single dressing, providing a better and more cost-effective treatment for wounds.
References
Gottrup F. A specialized wound-healing center concept: importance of a multidisciplinary department structure and surgical treatment facilities in the treatment of chronic wounds. Am J Surg 2004;187(5A):38S–43S.
Crovetti G, Martinelli G, Issi M, et al. Platelet gel for healing cutaneous chronic wounds. Transfus Apher Sci 2004;30(2):145–51.
Sen CK, Gordillo GM, Roy S, et al. Human skin wounds: a major and snowballing threat to public health and the economy. Wound Repair Regen 2009;17(6):763–71.
Mehmood N, Hariz A, Templeton S, Voelcker NH. An improved flexible telemetry system to autonomously monitor sub-bandage pressure and wound moisture. Sensors (Basel) 2014;14(11):21770–90.
Harding KG, Morris HL, Patel GK. Science, medicine, and the future: healing chronic wounds. BMJ 2002;324(7330):160–3.
Koetse M, Rensing P, Van Heck G, et al. In Plane Optical Sensor Based on Organic Electronic Devices. Conference Paper in Proceedings of SPIE—The International Society for Optical Engineering, 0–8; 2008.
Matzeu G, Losacco M, Parducci E, et al. Skin temperature monitoring by a wireless sensor. IECON 2011—37th Annual Conference of the IEEE Industrial Electronics Society, Melbourne, Victoria, 2011;3533–5.
McColl D, Macdougall M, Watret L, Connolly P. Monitoring moisture without disturbing the wound dressing. Wounds UK 2009;5(3):94–9.
Mostafalu P, Lenk W, Dokmeci MR, Ziaie B, Khademhosseini A, Sonkusale SR. Wireless flexible smart bandage for continuous monitoring of wound oxygenation. IEEE Trans Biomed Circuits Syst 2015;9(5):670–7.
Sharp D, Davis J. Integrated urate sensors for detecting wound infection. Electrochem Commun 2008;10:709–13.
Ochoa M, Member S, Rahimi R, Ziaie B, Member S. Flexible sensors for chronic wound management. IEEE Rev Biomed Eng 2014;7:73–86.
Kassal P, Kim J, Kumar R, et al. Smart bandage with wireless connectivity for uric acid biosensing as an indicator of wound status. Electrochem Commun 2015;56:6–10.
Pasche S, Angeloni S, Ischer R, Liley M, Luprano J, Voirin G. Wearable biosensors for monitoring wound healing. Adv Sci Technol 2008;57:80–7.
Sharp D, Gladstone P, Smith RB, Forsythe S, Davis J. Bioelectrochemistry approaching intelligent infection diagnostics: carbon fibre sensor for electrochemical pyocyanin detection. Bioelectrochemistry 2010;77(2):114–9.
Hariz A, Mehmood N, Voelcker N. Sub-bandage sensing system for remote monitoring of chronic wounds in healthcare. Proc SPIE 2015;9668:1–10.
Mehmood N, Hariz A, Templeton S, Voelcker N. An innovative sensing technology for chronic wound monitoring. Australian Biomedical Engineering Conference, Canberra, Australia; 2014:20–2.
Babikian S, Li GP, Bachman M. Integrated bioflexible electronic device for electrochemical analysis of blood. Proceedings—Electronic Components and Technology Conference 2015:685–90.
Yang B, Kong J, Fang X. Bandage-like wearable flexible microfluidic recombinase polymerase amplification sensor for the rapid visual detection of nucleic acids. Talanta 2019;204(1):685–92.
Zepon K, Martins M, Marques M, et al. Smart wound dressing based on κ–carrageenan/locust bean gum/cranberry extract for monitoring bacterial infections. Carbohydr Polym 2019;206:362–70.
Bazbouz M, Tronci G. Two-layer electrospun system enabling wound exudate management and visual infection response. Sensors (Basel) 2019;19(5):991.
Upton D, Solowiej K, Hender C, Woodyatt KY. Stress and pain associated with dressing change in chronic wound patients. J Wound Care 2012;21(2):53–5.
Deutsch CD, Edwards DM, Myers S. Wound dressings. Br J Hosp Med 2017;78(7):103–9.
Moura LI, Dias AM, Carvalho E, de Sousa HC. Recent advances on the development of wound dressings for diabetic foot ulcer treatment—a review. Acta Biomater 2013;9(7):7093–114.
Skafjeld A, Iversen MM, Holme I, Ribu L, Hvaal K, Kilhovd BK. A pilot study testing the feasibility of skin temperature monitoring to reduce recurrent foot ulcers in patients with diabetes—a randomized controlled trial. BMC Endocr Disord 2015;9(15):55–61.
Mehmood N, Hariz A, Fitridge R, Voelcker NH. Applications of modern sensors and wireless technology in effective wound management. J Biomed Mater Res Part B 2013;102:885–95.
Sharpe JR, Booth S, Jubin K, Jordan NR, Lawrence-Watt DJ, Dheansa BS. Progression of wound pH during the course of healing in burns. J Burn Care Res 2013;34:201–8.
Rahimi R, Ochoa M, Parupudi T, et al. A low-cost flexible pH sensor array for wound assessment. Sens Actuators B Chem 2016;229:609–17.
Thet NT, Jenkins ATA. An electrochemical sensor concept for the detection of bacterial virulence factors from Staphylococcus aureus and Pseudomonas aeruginosa . Electrochem Commun 2015;59:104–8.