The present paper provides a description of the design, characterization, and use of a Hg selective electrode (Hg-SE) for the determination of Hg at ultra-traces levels in a variety of real samples. The ionophore in the proposed electrode is a new Schiff base, namely 4-bromo-2-[(4-methoxyphenylimino)methyl]phenol (BMPMP). All factors affecting electrode response including polymeric membrane composition, concentration of internal solution, pH sample solution, and response time were optimized. The optimum response of our electrode was obtained with the following polymeric membrane composition (% /): PVC, 32; -NPOE, 64.5; BMPMP, 2 and NaTPB, 1.5. The potentiometric response of Hg-SE towards Hg ion was linear in the wide range of concentrations (9.33 × 10-3.98 × 10 molL), while, the limit of detection of the proposed electrode was 3.98 × 10 molL (8.00 μg L). The Hg-SE responds quickly to Hg ions as the response time of less than 10 s. On the other hand, the slope value obtained for the developed electrode was 29.74 ± 0.1 mV/decade in the pH range of 2.0-9.0 in good agreement with the Nernstian response (29.50 mV/decade). The Hg-SE has relatively less interference with other metal ions. The Hg-SE was used as an indicator electrode in potentiometric titrations to estimate Hg ions in waters, compact fluorescent lamp, and dental amalgam alloy and the accuracy of the developed electrode was compared with ICP-OES measurement values. Moreover, the new Schiff base (BMPMP) was synthesized and characterized using ATR-FTIR, elemental analysis, H NMR, and C NMR. The PVC membranes containing BMPMP as an ionophore unloaded and loaded with Hg(II) are reported by scanning electron microscope images (SEM) along with energy-dispersive X-ray spectroscopy (EDX) spectra.

Keywords

References

  1. Biosens Bioelectron. 2015 Jan 15;63:276-286 [PMID: 25108108]
  2. Anal Chim Acta. 2012 Oct 9;746:98-106 [PMID: 22975186]
  3. Sensors (Basel). 2014 Jul 21;14(7):13102-13 [PMID: 25051034]
  4. Talanta. 2013 Sep 30;114:235-42 [PMID: 23953465]
  5. J Food Drug Anal. 2018 Apr;26(2):670-677 [PMID: 29567237]
  6. J Hazard Mater. 2010 Jun 15;178(1-3):287-92 [PMID: 20149525]
  7. J Anal Toxicol. 2007 Jun;31(5):281-7 [PMID: 17579973]
  8. Analyst. 2014 May 7;139(9):2133-6 [PMID: 24647405]
  9. Anal Bioanal Chem. 2013 Jan;405(1):287-95 [PMID: 23104313]
  10. Mater Sci Eng C Mater Biol Appl. 2017 Mar 1;72:26-33 [PMID: 28024585]
  11. Small. 2013 May 27;9(9-10):1467-81 [PMID: 22961942]
  12. Environ Health Perspect. 2014 Jul;122(7):667-72 [PMID: 24682486]
  13. Met Based Drugs. 2008;2008:875410 [PMID: 18670613]
  14. Mikrochim Acta. 2018 Jul 2;185(7):351 [PMID: 29968011]
  15. Mikrochim Acta. 2019 Dec 17;187(1):56 [PMID: 31848777]
  16. Anal Sci. 2006 Jun;22(6):861-4 [PMID: 16772686]
  17. RSC Adv. 2020 Jul 1;10(42):25100-25106 [PMID: 35517435]
  18. Talanta. 2017 Aug 15;171:213-219 [PMID: 28551131]
  19. Analyst. 2013 Jun 21;138(12):3494-501 [PMID: 23666232]
  20. Mikrochim Acta. 2018 Sep 15;185(10):461 [PMID: 30219975]
  21. Talanta. 2005 Apr 30;66(3):575-80 [PMID: 18970023]
  22. J Anal Methods Chem. 2020 Dec 18;2020:8867653 [PMID: 33381352]
  23. Anal Sci. 2009 Apr;25(4):567-70 [PMID: 19359801]
  24. Biol Trace Elem Res. 2021 Mar;199(3):1161-1169 [PMID: 32472353]
  25. Crit Rev Anal Chem. 2011 Oct-Dec;41(4):282-313 [PMID: 28094545]
  26. J Hazard Mater. 2009 Aug 15;167(1-3):602-8 [PMID: 19195781]
  27. Anal Sci. 2002 Jul;18(7):811-4 [PMID: 12137378]
  28. Talanta. 2003 Jan 2;59(1):101-5 [PMID: 18968889]
  29. Anal Chim Acta. 2013 Jan 25;761:11-7 [PMID: 23312309]
  30. J Hazard Mater. 2010 Nov 15;183(1-3):402-9 [PMID: 20692088]
  31. Anal Chim Acta. 2007 May 2;590(1):81-90 [PMID: 17416226]
  32. Anal Sci. 2004 May;20(5):811-4 [PMID: 15171285]
  33. Talanta. 2012 May 15;93:32-6 [PMID: 22483872]
  34. Talanta. 2004 Jan 9;62(1):123-9 [PMID: 18969273]
  35. Talanta. 2003 May 28;60(1):73-80 [PMID: 18969027]

Grants

  1. 1-438-5996/Taif University

Word Cloud

Created with Highcharts 10.0.0electrodeHgresponseHg-SESchiffBMPMPionophorebasemembranePVC×10ionsselectiveproposednewpolymericcompositionsolutionpHtimeobtained521potentiometricrange98molLlessdeveloped290mV/decadeNMRIIpresentpaperprovidesdescriptiondesigncharacterizationusedeterminationultra-traceslevelsvarietyrealsamplesnamely4-bromo-2-[4-methoxyphenyliminomethyl]phenolfactorsaffectingincludingconcentrationinternalsampleoptimizedoptimumfollowing%/:32-NPOE64NaTPBtowardsionlinearwideconcentrations93310-3limitdetection3800μgLrespondsquicklyshandslopevalue74±0-9goodagreementNernstian50relativelyinterferencemetalusedindicatortitrationsestimatewaterscompactfluorescentlampdentalamalgamalloyaccuracycomparedICP-OESmeasurementvaluesMoreoversynthesizedcharacterizedusingATR-FTIRelementalanalysisHCmembranescontainingunloadedloadedreportedscanningelectronmicroscopeimagesSEMalongenergy-dispersiveX-rayspectroscopyEDXspectraDesignCharacterizationElectrochemicalSensorDeterminationMercuryIonRealSamplesBaseduponNewBaseDerivativeIonophoreISE-Hgmercury

Similar Articles

Cited By