Abstract

Compare the sensitivity and specificity of cVEMP (500 Hz), oVEMP (500 Hz and 4 kHz) in the identification of SSCD. A secondary objective was to identify the influence of dehiscence size and location on cVEMP and oVEMP responses. : Individuals with unilateral (n = 16) and bilateral (n = 10) scan confirmed SSCD were assessed using air-conducted cVEMP and oVEMP : For cVEMP, an amplitude cutoff of 286.9 μV or a threshold cutoff of 67.5 dBnHL revealed, respectively, a sensitivity of 75% and 70.6% and a specificity of 69.4% and 100%. For oVEMP (500 Hz), an amplitude cutoff of 10.8 μV or a threshold cutoff of 77.5 dBnHL revealed a sensitivity of 83.33% and a specificity of 87.5% and 80%, respectively. oVEMP (4 kHz), an amplitude cutoff of 3.1 μV, revealed a high specificity of 100% but a low sensitivity of 47.2%. A positive correlation was noted between the length of the SSCD and the cVEMP and oVEMP (500 Hz) thresholds and cVEMP amplitude. : Our results support the use of oVEMP in the identification of SSCD. The presence of oVEMP (500 Hz) with an amplitude higher or equal to 10.8 μV, a threshold lower or equal to 77.5 dBnHL or oVEMP (4 kHz) amplitude of 3.1 μV represents the most useful to identify SSCD.

Keywords

References

  1. Eur Arch Otorhinolaryngol. 2021 Apr;278(4):997-1015 [PMID: 32592013]
  2. Clin Neurophysiol. 2004 Nov;115(11):2567-73 [PMID: 15465446]
  3. Otolaryngol Head Neck Surg. 2013 Jul;149(1):142-5 [PMID: 23674567]
  4. Clin Neurophysiol. 2016 Jun;127(6):2522-31 [PMID: 27105578]
  5. Sci Rep. 2018 Jul 6;8(1):10257 [PMID: 29980716]
  6. Ear Hear. 2013 Jul-Aug;34(4):482-90 [PMID: 23361360]
  7. J Physiol. 2012 Jul 1;590(13):3091-101 [PMID: 22526888]
  8. Otol Neurotol. 2019 Dec;40(10):1353-1358 [PMID: 31725592]
  9. Front Neurol. 2020 Jul 21;11:695 [PMID: 32793102]
  10. Rev Laryngol Otol Rhinol (Bord). 2008;129(1):17-26 [PMID: 18777765]
  11. Front Neurol. 2017 Apr 28;8:177 [PMID: 28503164]
  12. Otol Neurotol. 2008 Aug;29(5):699-705 [PMID: 18520628]
  13. Otol Neurotol. 2013 Jan;34(1):127-34 [PMID: 23151775]
  14. Acta Otolaryngol. 2021 May;141(5):471-475 [PMID: 33641579]
  15. Radiology. 2006 Mar;238(3):938-42 [PMID: 16424241]
  16. Otolaryngol Head Neck Surg. 2009 Dec;141(6):689-94 [PMID: 19932839]
  17. Clin Exp Otorhinolaryngol. 2019 Aug;12(3):249-254 [PMID: 30458602]
  18. Otolaryngol Head Neck Surg. 2017 May;156(5):917-923 [PMID: 28168887]
  19. Nat Neurosci. 2017 Oct 26;20(11):1465-1473 [PMID: 29073639]
  20. Eur Arch Otorhinolaryngol. 2014 Nov;271(11):2905-14 [PMID: 24162764]
  21. Otol Neurotol. 2013 Jan;34(1):121-6 [PMID: 23183641]
  22. Clin Neurophysiol. 2009 Jul;120(7):1386-91 [PMID: 19464947]
  23. Otol Neurotol. 2014 Feb;35(2):338-43 [PMID: 24448294]
  24. Ear Hear. 2019 Mar/Apr;40(2):287-294 [PMID: 29889159]
  25. Otol Neurotol. 2007 Oct;28(7):920-6 [PMID: 17955609]
  26. Otol Neurotol. 2013 Oct;34(8):1421-8 [PMID: 23644303]
  27. Audiol Neurootol. 2014;19(2):97-105 [PMID: 24434937]
  28. J Int Adv Otol. 2021 Mar;17(2):103-108 [PMID: 33893778]
  29. J Vestib Res. 1999;9(5):327-34 [PMID: 10544371]
  30. Exp Brain Res. 2017 Apr;235(4):957-972 [PMID: 28130556]
  31. Clin Neurophysiol Pract. 2019 Feb 26;4:47-68 [PMID: 30949613]

Word Cloud

Created with Highcharts 10.0.0oVEMPcVEMPamplitude500HzSSCDcutoffμVsensitivityspecificity4kHz:10threshold5dBnHLrevealedidentificationidentifydehiscencen=respectively100%87731equalDehiscencevestibularComparesecondaryobjectiveinfluencesizelocationresponsesIndividualsunilateral16bilateralscanconfirmedassessedusingair-conducted28696775%706%694%8333%875%80%highlow472%positivecorrelationnotedlengththresholdsresultssupportusepresencehigherlowerrepresentsusefulInvestigatingPerformanceIdentificationSuperiorCanalRelationLocationSizesuperiorsemicircularcanalevokedmyogenicpotentials

Similar Articles

Cited By