Poor ventilation worsens short-range airborne transmission of respiratory infection.

Yuguo Li, Pan Cheng, Wei Jia
Author Information
  1. Yuguo Li: Department of Mechanical Engineering, The University of Hong Kong, Hong Kong SAR, China. ORCID
  2. Pan Cheng: Department of Mechanical Engineering, The University of Hong Kong, Hong Kong SAR, China.
  3. Wei Jia: Department of Mechanical Engineering, The University of Hong Kong, Hong Kong SAR, China. ORCID

Abstract

To explain the observed phenomenon that most SARS-CoV-2 transmission occurs indoors whereas its outdoor transmission is rare, a simple macroscopic aerosol balance model is developed to link short- and long-range airborne transmission. The model considers the involvement of exhaled droplets with initial diameter ≤50 µm in the short-range airborne route, whereas only a fraction of these droplets with an initial diameter within 15 µm or equivalently a final diameter within 5 µm considered in the long-range airborne route. One surprising finding is that the room ventilation rate significantly affects the short-range airborne route, in contrast to traditional belief. When the ventilation rate in a room is insufficient, the airborne infection risks due to both short- and long-range transmission are high. A ventilation rate of 10 L/s per person provides a similar concentration vs distance decay profile to that in outdoor settings, which provides additional justification for the widely adopted ventilation standard of 10 L/s per person. The newly obtained data do not support the basic assumption in the existing ventilation standard ASHRAE 62.1 (2019) that the required people outdoor air rate is constant if the standard is used directly for respiratory infection control. Instead, it is necessary to increase the ventilation rate when the physical distance between people is less than approximately 2 m.

Keywords

References

  1. Indoor Air. 2007 Jun;17(3):211-25 [PMID: 17542834]
  2. Build Simul. 2009;2(4):281-289 [PMID: 32218907]
  3. J R Soc Interface. 2019 Jan 31;16(150):20180298 [PMID: 30958176]
  4. J Hyg (Lond). 1946 Sep;44(6):471-9 [PMID: 20475760]
  5. PLoS Pathog. 2013 Mar;9(3):e1003205 [PMID: 23505369]
  6. Appl Microbiol Biotechnol. 2006 Dec;73(3):703-12 [PMID: 17053902]
  7. Build Environ. 2009 Jul;44(7):1378-1385 [PMID: 32288004]
  8. Indoor Air. 2017 Mar;27(2):452-462 [PMID: 27287598]
  9. Indoor Air. 2017 Jan;27(1):179-190 [PMID: 26945674]
  10. Proc Natl Acad Sci U S A. 2021 Apr 20;118(16): [PMID: 33811185]
  11. Clin Infect Dis. 2020 Dec 3;71(9):2311-2313 [PMID: 32628269]
  12. Ann N Y Acad Sci. 1964 Jul 30;116:630-7 [PMID: 14220559]
  13. Proc Natl Acad Sci U S A. 2020 Oct 13;117(41):25237-25245 [PMID: 32978297]
  14. Indoor Air. 2021 May;31(3):639-645 [PMID: 33131151]
  15. Indoor Air. 2003 Sep;13(3):237-45 [PMID: 12950586]
  16. Am J Epidemiol. 1978 May;107(5):421-32 [PMID: 665658]
  17. Indoor Air. 2013 Feb;23(1):62-73 [PMID: 22680621]
  18. Proc Natl Acad Sci U S A. 2018 Jan 30;115(5):1081-1086 [PMID: 29348203]
  19. Indoor Air. 2022 Jan;32(1):e12946 [PMID: 34704625]
  20. Indoor Air. 2021 Mar;31(2):314-323 [PMID: 32979298]
  21. Indoor Air. 2021 Mar;31(2):369-382 [PMID: 32869358]
  22. Indoor Air. 2000 Jun;10(2):68-73 [PMID: 11980104]

Grants

  1. /Research Grants Council, University Grants Committee

MeSH Term

Aerosols
Air Microbiology
Air Pollution, Indoor
COVID-19
Humans
Respiratory Tract Infections
SARS-CoV-2
Ventilation

Chemicals

Aerosols

Word Cloud

Created with Highcharts 10.0.0airborneventilationtransmissionratelong-rangeshort-rangeinfectionoutdoordiameterroutestandardrespiratorySARS-CoV-2whereasmodelshort-dropletsinitialwithinroom10 L/sperpersonprovidesdistancepeopleexplainobservedphenomenonoccursindoorsraresimplemacroscopicaerosolbalancedevelopedlinkconsidersinvolvementexhaled≤50 µmfraction15 µmequivalentlyfinal5 µmconsideredOnesurprisingfindingsignificantlyaffectscontrasttraditionalbeliefinsufficientrisksduehighsimilarconcentrationvsdecayprofilesettingsadditionaljustificationwidelyadoptednewlyobtaineddatasupportbasicassumptionexistingASHRAE6212019requiredairconstantuseddirectlycontrolInsteadnecessaryincreasephysicallessapproximately2 mPoorworsensclosecontactexpiredjet

Similar Articles

Cited By