Influence of glenoid wear pattern on glenoid component placement accuracy in shoulder arthroplasty.

Kevin A Hao, Christopher D Sutton, Thomas W Wright, Bradley S Schoch, Jonathan O Wright, Aimee M Struk, Edward T Haupt, Thiago Leonor, Joseph J King
Author Information
  1. Kevin A Hao: College of Medicine, University of Florida, Gainesville, FL, USA.
  2. Christopher D Sutton: Department of Orthopaedics & Rehabilitation, University of Florida, Gainesville, FL, USA.
  3. Thomas W Wright: Department of Orthopaedics & Rehabilitation, University of Florida, Gainesville, FL, USA.
  4. Bradley S Schoch: Department of Orthopaedic Surgery, Mayo Clinic, Jacksonville, FL, USA.
  5. Jonathan O Wright: Department of Orthopaedics & Rehabilitation, University of Florida, Gainesville, FL, USA.
  6. Aimee M Struk: Department of Orthopaedics & Rehabilitation, University of Florida, Gainesville, FL, USA.
  7. Edward T Haupt: Department of Orthopaedic Surgery, Mayo Clinic, Jacksonville, FL, USA.
  8. Thiago Leonor: Inverted TEA LLC, Gainesville, FL, USA.
  9. Joseph J King: Department of Orthopaedics & Rehabilitation, University of Florida, Gainesville, FL, USA.

Abstract

BACKGROUND: Accurate glenoid component placement in shoulder arthroplasty is often difficult even with the use of preoperative planning. Computer navigation and patient-specific guides increase component placement accuracy, but which patients benefit most is unknown. Our purpose was to assess surgeons' accuracy in placing a glenoid component in vivo using 3-dimensional preoperative planning and standard instruments among various glenoid wear patterns.
METHODS: We conducted a retrospective review of 170 primary anatomic total shoulder arthroplasty (aTSA) and reverse total shoulder arthroplasty (rTSA) performed at a single institution. Commercially available preoperative planning software was used in all arthroplasties with multiplanar 2-dimensional computed tomography and a 3-dimensional implant overlay. After registration of intraoperative bony landmarks to the navigation system, participating surgeons with knowledge of the preoperative plan were blinded to the computer screen and attempted to implement their preoperative plan by simulating placement of a central-axis glenoid guide pin. Two hundred thirty-three screenshots of surgeon's simulated guide pin placement were included. Glenoid displacement, error in version and inclination, and overall malposition from the preoperatively planned target point were stratified by posterior wear status (with [Walch B2 or B3] or without [A1, A2, or B1]) and Walch classification (A1, A2, B1, B2, or B3). The glenoid component was considered malpositioned when version or inclination errors exceeded 10° or the starting point displacement exceeded 4 mm.
RESULTS: For rTSA, errors in version were greater for glenoids with posterior wear compared with those without (8.1° ± 5.6° vs. 4.7° ± 4.0°;  < .001). On post hoc analysis, B2 glenoids had greater version error than A1, A2, and B1 glenoids. A greater proportion of glenoids undergoing rTSA that possessed posterior wear had an error in version >10° compared with those without (31% vs. 8%;  < .001). Consequently, glenoids undergoing rTSA with posterior wear were malpositioned at a greater rate compared with those without (73% vs. 53%). In contrast, glenoids undergoing aTSA with and without posterior wear did not differ based on displacement error, version error, inclination error, or malposition occurrence.
CONCLUSIONS: Posterior glenoid bone loss more commonly resulted in glenoid version errors exceeding 10 degrees and component malposition in rTSA, but not for aTSA. Malposition was still relatively high in patients without significant posterior wear for both aTSA (36%) and rTSA (53%). Surgeons should consider alternate techniques beyond preoperative planning and standard instrumentation when performing shoulder arthroplasty in patients with posteriorly worn glenoids.

Keywords

References

  1. Bone Joint J. 2016 Aug;98-B(8):1080-5 [PMID: 27482021]
  2. J Bone Joint Surg Am. 2015 Apr 15;97(8):651-8 [PMID: 25878309]
  3. J Bone Joint Surg Am. 2014 May 7;96(9):e71 [PMID: 24806017]
  4. Acta Biomed. 2020 May 30;91(4-S):204-208 [PMID: 32555098]
  5. Arch Orthop Trauma Surg. 2015 Jan;135(1):41-7 [PMID: 25450305]
  6. J Shoulder Elbow Surg. 2019 Dec;28(12):e398-e409 [PMID: 31353300]
  7. Clin Orthop Relat Res. 2011 Sep;469(9):2496-504 [PMID: 21328021]
  8. Int Orthop. 2018 Dec;42(12):2897-2906 [PMID: 29968136]
  9. Orthop Traumatol Surg Res. 2016 Dec;102(8):1029-1034 [PMID: 28341264]
  10. Curr Rev Musculoskelet Med. 2016 Mar;9(1):1-9 [PMID: 26809956]
  11. J Shoulder Elbow Surg. 2021 Jun;30(6):1273-1281 [PMID: 33069903]
  12. J Shoulder Elbow Surg. 2017 Aug;26(8):1469-1476 [PMID: 28161240]
  13. J Am Acad Orthop Surg. 2019 Mar 15;27(6):200-209 [PMID: 30260909]
  14. J Bone Joint Surg Am. 2008 Nov;90(11):2438-45 [PMID: 18978413]
  15. J Shoulder Elbow Surg. 2016 Feb;25(2):186-92 [PMID: 26456430]
  16. J Bone Joint Surg Am. 2013 Jun 19;95(12):e82 [PMID: 23783213]
  17. J Bone Joint Surg Am. 2012 Dec 5;94(23):2167-75 [PMID: 23224387]
  18. Bone Joint J. 2020 Nov;102-B(11):1438-1445 [PMID: 33135432]
  19. Arch Bone Jt Surg. 2021 Jan;9(1):64-69 [PMID: 33778117]
  20. J Shoulder Elbow Surg. 2006 Jul-Aug;15(4):521-6 [PMID: 16831661]
  21. J Shoulder Elbow Surg. 2015 Jun;24(6):965-71 [PMID: 25535020]
  22. J Shoulder Elbow Surg. 2007 May-Jun;16(3 Suppl):S79-83 [PMID: 17493558]
  23. J Shoulder Elbow Surg. 2016 Oct;25(10):1601-6 [PMID: 27282738]
  24. Bull Hosp Jt Dis (2013). 2015 Dec;73 Suppl 1:S47-51 [PMID: 26631196]
  25. J Knee Surg. 2013 Oct;26(5):357-61 [PMID: 23512544]
  26. J Bone Joint Surg Am. 2018 Jul 5;100(13):1095-1103 [PMID: 29975263]
  27. J Shoulder Elbow Surg. 2015 May;24(5):682-90 [PMID: 25487904]
  28. J Arthroplasty. 2021 Feb;36(2):560-565 [PMID: 32854994]
  29. J Arthroplasty. 1999 Sep;14(6):756-60 [PMID: 10512449]
  30. Clin Orthop Relat Res. 2015 Jan;473(1):151-8 [PMID: 25059850]
  31. J Shoulder Elbow Surg. 2020 Nov;29(11):2257-2263 [PMID: 32586595]
  32. J Shoulder Elbow Surg. 2011 Jan;20(1):21-6 [PMID: 21134663]
  33. J Bone Joint Surg Am. 2003 Feb;85(2):251-8 [PMID: 12571302]
  34. J Shoulder Elbow Surg. 2017 Aug;26(8):1477-1483 [PMID: 28162884]
  35. Clin Orthop Surg. 2017 Jun;9(2):213-217 [PMID: 28567225]
  36. J Shoulder Elbow Surg. 2020 Mar;29(3):617-623 [PMID: 31648783]

Word Cloud

Created with Highcharts 10.0.0glenoidwearversionglenoidscomponentpreoperativerTSAerrorposteriorwithoutplacementshoulderarthroplastyplanningaTSAgreateraccuracypatientsdisplacementinclinationmalpositionB2A2errorscomparedvsundergoingnavigation3-dimensionalstandardtotalplanguidepinpointWalchclassificationA1B1malpositionedexceeded4<00153%BACKGROUND:AccurateoftendifficultevenuseComputerpatient-specificguidesincreasebenefitunknownpurposeassesssurgeons'placingin vivousinginstrumentsamongvariouspatternsMETHODS:conductedretrospectivereview170primaryanatomicreverseperformedsingleinstitutionCommerciallyavailablesoftwareusedarthroplastiesmultiplanar2-dimensionalcomputedtomographyimplantoverlayregistrationintraoperativebonylandmarkssystemparticipatingsurgeonsknowledgeblindedcomputerscreenattemptedimplementsimulatingcentral-axisTwohundredthirty-threescreenshotssurgeon'ssimulatedincludedGlenoidoverallpreoperativelyplannedtargetstratifiedstatus[WalchB3][A1B1]B3considered10°startingmmRESULTS:81° ± 57° ± 4posthocanalysisproportionpossessed>10°31%8%Consequentlyrate73%contrastdifferbasedoccurrenceCONCLUSIONS:Posteriorbonelosscommonlyresultedexceeding10degreesMalpositionstillrelativelyhighsignificant36%SurgeonsconsideralternatetechniquesbeyondinstrumentationperformingposteriorlywornInfluencepatternArthroplastyErrorInclinationNavigationOutliersPlanningShoulderreplacement

Similar Articles