Comparative study of the effect of N95 facemask and Powered Air-purifying Respirator (2 fans, N95 filter) on cardiovascular parameters of healthy individuals during exercise.

Abhijith K Anil, Raihan Mannan, K Shanmugasundaram, Geetanjali Bade, Anjana Talwar, Kishore K Deepak
Author Information
  1. Abhijith K Anil: Department of Physiology, All India Institute of Medical Sciences, New Delhi, India.
  2. Raihan Mannan: Department of Physiology, All India Institute of Medical Sciences, New Delhi, India.
  3. K Shanmugasundaram: Department of Physiology, All India Institute of Medical Sciences, New Delhi, India.
  4. Geetanjali Bade: Department of Physiology, All India Institute of Medical Sciences, New Delhi, India.
  5. Anjana Talwar: Department of Physiology, All India Institute of Medical Sciences, New Delhi, India.
  6. Kishore K Deepak: Department of Physiology, All India Institute of Medical Sciences, New Delhi, India.

Abstract

N95 masks filter 95% of the small particles and respiratory droplets (>0.3 µm diameter). Therefore, they are widely used both by general public and health workers during pandemic. When physical activity or exercise is performed wearing N95 mask, it induces hypercapnic environment. The heat burden is also increased leading to discomfort and reduced compliance. This study was done to compare physiological effects and subjective perceptions while wearing N95 mask and powered air-purifying respirator (PAPR) (2 fans, N95 filter) during incremental exercise. ECG, respiratory movement, SpO temperature inside the mask were recorded and perception of discomfort was also assessed. Heart rate variability (HRV) values during baseline were within normal limits in both the mask conditions signifying that cardiac autonomic tone is comparable. During incremental exercise, fall in SpO was significantly lesser in PAPR as compared to N95 mask at 60-70% and 70-80% of maximum achievable heart rate. The temperatures inside both the mask conditions were significantly higher than ambient temperature. The scores of humid, hot, breath resistance and fatigue were significantly lower in PAPR than N95 mask. In conditions where prolonged use of mask is required with strenuous physical exertion or exercise, PAPR could be preferred over N95 mask.

Keywords

References

  1. Influenza Other Respir Viruses. 2011 May;5(3):170-9 [PMID: 21477136]
  2. Respir Care. 2010 May;55(5):569-77 [PMID: 20420727]
  3. Scand J Med Sci Sports. 2021 Jan;31(1):70-75 [PMID: 32969531]
  4. Int Arch Occup Environ Health. 2005 Jul;78(6):501-9 [PMID: 15918037]
  5. Lancet. 2020 Mar 7;395(10226):809-815 [PMID: 32151335]
  6. J Occup Environ Hyg. 2017 Dec;14(12):947-954 [PMID: 28763290]
  7. Cochrane Database Syst Rev. 2020 Apr 4;4:CD010596 [PMID: 32246780]
  8. Am Ind Hyg Assoc J. 1997 Dec;58(12):881-4 [PMID: 9425649]
  9. J Appl Physiol (1985). 1998 Aug;85(2):609-18 [PMID: 9688739]
  10. Respirology. 2005 Jan;10(1):107-10 [PMID: 15691247]
  11. Clin Chest Med. 1997 Mar;18(1):1-17 [PMID: 9098607]
  12. Circulation. 1996 Mar 1;93(5):1043-65 [PMID: 8598068]
  13. Ann Occup Hyg. 2010 Aug;54(6):671-7 [PMID: 20522519]
  14. Curr Opin Infect Dis. 2019 Aug;32(4):372-379 [PMID: 31259864]
  15. Acta Neurol Scand. 2019 Nov;140(5):350-358 [PMID: 31343735]
  16. Physiol Rev. 2017 Oct 1;97(4):1351-1402 [PMID: 28814614]
  17. J Appl Physiol (1985). 2020 May 1;128(5):1271-1279 [PMID: 32163324]

MeSH Term

Humans
Masks
Respiratory Protective Devices
Exercise
Heart Rate
Pandemics

Word Cloud

Created with Highcharts 10.0.0N95maskexercisePAPRfilterconditionssignificantlyrespiratoryphysicalwearingalsodiscomfortstudy2fansincrementalSpOtemperatureinsiderateHRVmasks95%smallparticlesdroplets>03µmdiameterThereforewidelyusedgeneralpublichealthworkerspandemicactivityperformedinduceshypercapnicenvironmentheatburdenincreasedleadingreducedcompliancedonecomparephysiologicaleffectssubjectiveperceptionspoweredair-purifyingrespiratorECGmovementrecordedperceptionassessedHeartvariabilityvaluesbaselinewithinnormallimitssignifyingcardiacautonomictonecomparablefalllessercompared60-70%70-80%maximumachievablehearttemperatureshigherambientscoreshumidhotbreathresistancefatiguelowerprolongeduserequiredstrenuousexertionpreferredComparativeeffectfacemaskPoweredAir-purifyingRespiratorcardiovascularparametershealthyindividualsCOVID-19CardiopulmonarytestCPET

Similar Articles

Cited By

No available data.