Intubation strategy in COVID-19 era: An observational study.

Aparna Sinha, Dinesh Punhani, Abhishek Sharma, Kumar Gaurav Dhakate, Nivedita Garg, Sangeeta Patro
Author Information
  1. Aparna Sinha: Department of Anesthesia, Max Institute of Laparoscopy, Endoscopy and Bariatric Surgery, Max Super Speciality Hospital, New Delhi, India.
  2. Dinesh Punhani: Department of Anesthesia, Max Institute of Laparoscopy, Endoscopy and Bariatric Surgery, Max Super Speciality Hospital, New Delhi, India.
  3. Abhishek Sharma: Department of Anesthesia, Max Institute of Laparoscopy, Endoscopy and Bariatric Surgery, Max Super Speciality Hospital, New Delhi, India.
  4. Kumar Gaurav Dhakate: Department of Anesthesia, Max Institute of Laparoscopy, Endoscopy and Bariatric Surgery, Max Super Speciality Hospital, New Delhi, India.
  5. Nivedita Garg: Department of Anesthesia, Max Institute of Laparoscopy, Endoscopy and Bariatric Surgery, Max Super Speciality Hospital, New Delhi, India.
  6. Sangeeta Patro: Department of Anesthesia, Max Institute of Laparoscopy, Endoscopy and Bariatric Surgery, Max Super Speciality Hospital, New Delhi, India.

Abstract

Background and Aims: Aerosol protection equipment aim at protecting the anaesthesiologist, from aerosol-borne infections, namely, severe acute respiratory syndrome corona virus-2.
Methods: We improvised the first-generation intubation box (IB) by increasing its dimensions, including heat and moisture exchanger with filter, suction catheter, and attaching arm sleeves to make a modified intubation box (MIB). The impact of IB, MIB and transparent sheets (TS) on the patient outcomes during airway management was evaluated.
Results: A significant difference in median (interquartile range in minutes) was observed in time to intubate between IB (4 [4-5]); TS (0.5 [0.3-0.5]) and MIB (0.3 [0.3-1.5]): P = 0.004); and airway devices; McCoy (0.5 [0.3-2]), CMac (0.5 [0.3-1.5]): P = 0.004. First-pass success was 100% with the TS, whereas more than three attempts were required with IB 66.7% and 5.2% with MIB. Video laryngoscope was associated with less airway-related adverse events (ARAEs). The need for mask ventilation (and hence possible aerosolisation) was maximum with IB. All the ARAEs resolved uneventfully. No breach of personal protective equipment was observed; none of the health-care professionals involved in patient care developed any symptoms suggestive of COVID-19.
Conclusion: Video laryngoscope is favourable for managing airway in COVID-19 times. In view of the ongoing pandemic and added protection that it offers, it is worthwhile to include the MIB in the armamentarium for managing the airway of patients with COVID-19.

Keywords

References

  1. Anaesthesia. 2020 Jun;75(6):785-799 [PMID: 32221970]
  2. World J Surg. 2020 Jul;44(7):2049-2050 [PMID: 32335692]
  3. N Engl J Med. 2020 May 14;382(20):1957-1958 [PMID: 32243118]
  4. J Chin Med Assoc. 2020 Jun;83(6):582 [PMID: 32304507]
  5. Indian J Anaesth. 2020 Apr;64(4):259-263 [PMID: 32362681]
  6. Indian J Anaesth. 2020 May;64(Suppl 2):S107-S115 [PMID: 32773848]
  7. Anaesthesia. 2020 Aug;75(8):1014-1021 [PMID: 32397008]

Word Cloud

Created with Highcharts 10.0.00IBMIBCOVID-19airway5[0intubationboxTS5]protectionequipmentpatientobserved3-1:P=004VideolaryngoscopeARAEsmanagingBackgroundAims:Aerosolaimprotectinganaesthesiologistaerosol-borneinfectionsnamelysevereacuterespiratorysyndromecoronavirus-2Methods:improvisedfirst-generationincreasingdimensionsincludingheatmoistureexchangerfiltersuctioncatheterattachingarmsleevesmakemodifiedimpacttransparentsheetsoutcomesmanagementevaluatedResults:significantdifferencemedianinterquartilerangeminutestimeintubate4[4-5]3-03devicesMcCoy3-2]CMacFirst-passsuccess100%whereasthreeattemptsrequired667%2%associatedlessairway-relatedadverseeventsneedmaskventilationhencepossibleaerosolisationmaximumresolveduneventfullybreachpersonalprotectivenonehealth-careprofessionalsinvolvedcaredevelopedsymptomssuggestiveConclusion:favourabletimesviewongoingpandemicaddedoffersworthwhileincludearmamentariumpatientsIntubationstrategyera:observationalstudyAerosolisationanaesthesia

Similar Articles

Cited By