Fast Analysis of Caffeic Acid-Related Molecules in Instant Coffee by Reusable Sonogel-Carbon Electrodes.

Laura Pigani, Cristina Rioli, Barbara Zanfrognini, Juan José García-Guzmán, José Maria Palacios-Santander, Laura María Cubillana-Aguilera
Author Information
  1. Laura Pigani: Dipartimento di Scienze Chimiche e Geologiche, Università degli Studi di Modena e Reggio Emilia, Via G. Campi, 103, 41125 Modena, Italy. ORCID
  2. Cristina Rioli: Dipartimento di Scienze Chimiche e Geologiche, Università degli Studi di Modena e Reggio Emilia, Via G. Campi, 103, 41125 Modena, Italy.
  3. Barbara Zanfrognini: Dipartimento di Scienze Chimiche e Geologiche, Università degli Studi di Modena e Reggio Emilia, Via G. Campi, 103, 41125 Modena, Italy. ORCID
  4. Juan José García-Guzmán: Instituto de Investigación e Innovación Biomédica de Cadiz (INiBICA), Hospital Universitario 'Puerta del Mar', Universidad de Cadiz, 11009 Cadiz, Spain.
  5. José Maria Palacios-Santander: Institute of Research on Electron Microscopy and Materials (IMEYMAT), Department of Analytical Chemistry, Faculty of Sciences, Campus de Excelencia Internacional del Mar, University of Cadiz, Campus Universitario de Puerto Real, Polígono del Río San Pedro S/N, 11510 Puerto Real, Cadiz, Spain. ORCID
  6. Laura María Cubillana-Aguilera: Institute of Research on Electron Microscopy and Materials (IMEYMAT), Department of Analytical Chemistry, Faculty of Sciences, Campus de Excelencia Internacional del Mar, University of Cadiz, Campus Universitario de Puerto Real, Polígono del Río San Pedro S/N, 11510 Puerto Real, Cadiz, Spain. ORCID

Abstract

Reusable Sonogel-Carbon electrodes containing carbon black (SNGC-CB) have been used for the electrochemical analysis of caffeic acid (CA) in real matrices. Measurements were firstly performed in standard solutions, in which SNGC-CB electrodes allowed the electrochemical determination of CA with high sensitivity and low limit of detection, equal to 0.76 μM. The presence of CB nanostructures in the formulation led to improved performances with respect to pristine SNGC electrodes. Then, measurements were performed in four instant coffees of different brands. A comparison between the results obtained by electrochemical, chromatographic and spectroscopic methods showed that SBGC-CB electrodes represent a simple and economic tool for the rapid assessment of caffeic acid-related molecules in instant coffees.

Keywords

References

  1. Molecules. 2022 May 11;27(10): [PMID: 35630565]
  2. Food Chem. 2022 Nov 1;393:133417 [PMID: 35691065]
  3. Compr Rev Food Sci Food Saf. 2020 Nov;19(6):3130-3158 [PMID: 33337063]
  4. Food Chem. 2016 Jan 1;190:506-512 [PMID: 26213003]
  5. J Agric Food Chem. 2001 Mar;49(3):1410-6 [PMID: 11312873]
  6. Mikrochim Acta. 2020 Apr 28;187(5):296 [PMID: 32347378]
  7. Nat Protoc. 2007;2(4):875-7 [PMID: 17446889]
  8. J Agric Food Chem. 2006 Jan 25;54(2):374-81 [PMID: 16417293]
  9. Colloids Surf B Biointerfaces. 2009 Oct 15;73(2):408-14 [PMID: 19615869]
  10. J Food Sci Technol. 2017 Jul;54(8):2324-2331 [PMID: 28740289]
  11. J Agric Food Chem. 2012 Sep 12;60(36):8773-5 [PMID: 22578138]
  12. Food Chem. 2011 Jun 15;126(4):1821-35 [PMID: 25213963]
  13. Int J Mol Sci. 2021 Aug 18;22(16): [PMID: 34445600]
  14. Food Chem. 2015 Apr 15;173:1059-65 [PMID: 25466125]

MeSH Term

Carbon
Coffee
Electrodes
Caffeic Acids
Electrochemical Techniques
Limit of Detection

Chemicals

Carbon
caffeic acid
Coffee
Caffeic Acids

Word Cloud

Created with Highcharts 10.0.0electrodeselectrochemicalcaffeicReusableSonogel-CarboncarbonblackSNGC-CBacidCAperformedinstantcoffeescontainingusedanalysisrealmatricesMeasurementsfirstlystandardsolutionsalloweddeterminationhighsensitivitylowlimitdetectionequal076μMpresenceCBnanostructuresformulationledimprovedperformancesrespectpristineSNGCmeasurementsfourdifferentbrandscomparisonresultsobtainedchromatographicspectroscopicmethodsshowedSBGC-CBrepresentsimpleeconomictoolrapidassessmentacid-relatedmoleculesFastAnalysisCaffeicAcid-RelatedMoleculesInstantCoffeeElectrodesSonogel–Carbonelectrodecoffeedifferentialpulsevoltammetrysensorpolyphenols

Similar Articles

Cited By

No available data.