Effects of rigid gas permeable contact lens on morphological parameters and vision-related quality of life in keratoconus patients.

Yue Xu, Yun Wang, Xiao-Feng Zhang
Author Information
  1. Yue Xu: Department of Ophthalmology, Dushu Lake Hospital Affiliated to Soochow University, Suzhou 215000, Jiangsu Province, China.
  2. Yun Wang: Department of Ophthalmology, Dushu Lake Hospital Affiliated to Soochow University, Suzhou 215000, Jiangsu Province, China.
  3. Xiao-Feng Zhang: Department of Ophthalmology, Dushu Lake Hospital Affiliated to Soochow University, Suzhou 215000, Jiangsu Province, China.

Abstract

AIM: To evaluate the effect of rigid gas permeable contact lens (RGP-CL) on corneal morphological parameters and vision-related quality of life in keratoconus (KC) patients.
METHODS: Totally 57 eyes of 30 KC patients who were followed-up for more than two years, including 17 RGP wearers (32 eyes) and 13 non-wearers (25 eyes) were retrospectively analyzed. Initial medical history and corneal topography were collected at baseline. Corneal topography, corneal aberration, optical coherence tomography, and vision-related quality of life questionnaires were performed at the last follow-up.
RESULTS: According to corneal topography, increase of the flattest keratometric values was higher in RGP wearers than in non-wearers (=0.038). The morphological parameters, including symmetry index of front corneal curvature (=0.004) and Baiocchi-Calossi-Versaci index front (=0.047), were lower in RGP wearers than in non-wearers. Vertical coma was smaller in RGP wearers than non-wearers in 3.0, 5.0, 6.0, and 7.0 mm pupil diameters, respectively (<0.05). The environmental triggering domain of ocular surface disease index was worse in RGP wearers as compared to non-wearers (=0.003). At the last follow-up, there were no significant differences in constituent ratios of KC progression, corneal thickness topography, epithelial thickness topography, morphological parameters of corneal topography, and other questionnaire scores between the two groups (all >0.05).
CONCLUSION: Long-term use of RGP does not worsen KC but may cause corneal epithelial remodeling to increase symmetry of corneal anterior surface, reduce corneal vertical coma and improve visual quality. However, RGP wearing causes a slight decrease in vision-related quality of life. The occurrence of ocular surface symptoms is mainly associated with environmental triggering factors.

Keywords

References

  1. PLoS One. 2022 Jul 8;17(7):e0270519 [PMID: 35802557]
  2. Cornea. 2020 Mar;39(3):386-393 [PMID: 31599780]
  3. Eye Contact Lens. 2011 Mar;37(2):99-105 [PMID: 21336035]
  4. Cornea. 2013 Dec;32(12):1544-8 [PMID: 24145634]
  5. Arch Ophthalmol. 2000 May;118(5):615-21 [PMID: 10815152]
  6. Arch Ophthalmol. 1998 Nov;116(11):1496-504 [PMID: 9823352]
  7. Cornea. 2015 Apr;34(4):359-69 [PMID: 25738235]
  8. Br J Ophthalmol. 2021 Feb;105(2):186-190 [PMID: 32317253]
  9. J Refract Surg. 2010 Apr;26(4):259-71 [PMID: 20415322]
  10. J Curr Ophthalmol. 2016 Aug 30;28(4):194-198 [PMID: 27830203]
  11. Cont Lens Anterior Eye. 2022 Jun;45(3):101559 [PMID: 34991971]
  12. Cornea. 2020 Feb;39(2):186-191 [PMID: 31490278]
  13. Invest Ophthalmol Vis Sci. 2013 Aug 09;54(8):5385-91 [PMID: 23882688]
  14. Ann Ophthalmol. 1977 Jun;9(6):767-8 [PMID: 911119]
  15. Cont Lens Anterior Eye. 2022 Feb;45(1):101520 [PMID: 34686431]
  16. Int J Ophthalmol. 2020 Jul 18;13(7):1124-1131 [PMID: 32685402]
  17. Cont Lens Anterior Eye. 2020 Dec;43(6):568-576 [PMID: 32238301]
  18. Asia Pac J Ophthalmol (Phila). 2020 Dec;9(6):557-564 [PMID: 33323709]
  19. Clin Exp Optom. 2013 Mar;96(2):219-24 [PMID: 23278637]
  20. Dtsch Arztebl Int. 2019 Mar 8;116(11):184-190 [PMID: 31014449]
  21. J Refract Surg. 2013 Mar;29(3):173-9 [PMID: 23446013]
  22. Cont Lens Anterior Eye. 2019 Oct;42(5):482-486 [PMID: 30808595]
  23. J Refract Surg. 2020 Dec 1;36(12):838-843 [PMID: 33295997]
  24. Sci Rep. 2020 Jan 28;10(1):1321 [PMID: 31992755]
  25. Cornea. 2020 Feb;39(2):263-270 [PMID: 31498247]
  26. Turk J Ophthalmol. 2020 Aug 26;50(4):234-244 [PMID: 32854468]
  27. Coll Antropol. 2013 Apr;37 Suppl 1:199-203 [PMID: 23837244]
  28. J Fr Ophtalmol. 2020 Dec;43(10):1078-1095 [PMID: 32972759]
  29. J Crohns Colitis. 2015 Dec;9(12):1108-12 [PMID: 26351387]
  30. Eye Contact Lens. 2018 Nov;44 Suppl 2:S314-S317 [PMID: 29373388]
  31. Optom Vis Sci. 2008 Nov;85(11):1091-9 [PMID: 18981924]
  32. Am J Ophthalmol. 2019 Jan;197:88-97 [PMID: 30240724]
  33. Ophthalmology. 2016 Mar;123(3):457-65.e2 [PMID: 26707415]
  34. Cornea. 2015 May;34(5):525-9 [PMID: 25782404]
  35. Invest Ophthalmol Vis Sci. 2016 Jul 1;57(9):OCT544-9 [PMID: 27482824]
  36. Curr Med Chem. 2020;27(4):523-548 [PMID: 30963963]
  37. Eye (Lond). 2020 Dec;34(12):2175-2196 [PMID: 32641797]
  38. Mediators Inflamm. 2018 Sep 2;2018:4285268 [PMID: 30245588]

Word Cloud

Created with Highcharts 10.0.0cornealRGPqualitytopographymorphologicalparametersvision-relatedlifewearersnon-wearersKC=00rigidgaspermeablecontactlenskeratoconuspatientseyesindexsurfacetwoincludingaberrationlastfollow-upincreasesymmetryfrontcoma05environmentaltriggeringocularthicknessepithelialAIM:evaluateeffectRGP-CLMETHODS:Totally5730followed-upyears17321325retrospectivelyanalyzedInitialmedicalhistorycollectedbaselineCornealopticalcoherencetomographyquestionnairesperformedRESULTS:Accordingflattestkeratometricvalueshigher038curvature004Baiocchi-Calossi-Versaci047lowerVerticalsmaller3567mmpupildiametersrespectively<0domaindiseaseworsecompared003significantdifferencesconstituentratiosprogressionquestionnairescoresgroups>0CONCLUSION:Long-termuseworsenmaycauseremodelinganteriorreduceverticalimprovevisualHoweverwearingcausesslightdecreaseoccurrencesymptomsmainlyassociatedfactorsEffects

Similar Articles

Cited By