Optimizing an Optical Cavity-Based Biosensor for Enhanced Sensitivity.

Marzhan Sypabekova, Aidan Hagemann, Jenna Kleiss, Cooper Morlan, Seunghyun Kim
Author Information
  1. Marzhan Sypabekova: Department of Electrical and Computer Engineering, Baylor University, Waco, TX 76798 USA. ORCID
  2. Aidan Hagemann: Department of Electrical and Computer Engineering, Baylor University, Waco, TX 76798 USA.
  3. Jenna Kleiss: Department of Electrical and Computer Engineering, Baylor University, Waco, TX 76798 USA.
  4. Cooper Morlan: Department of Electrical and Computer Engineering, Baylor University, Waco, TX 76798 USA.
  5. Seunghyun Kim: Department of Electrical and Computer Engineering, Baylor University, Waco, TX 76798 USA. ORCID

Abstract

The rapid advancement of biosensor technology has revolutionized healthcare, offering improved sensitivity, specificity, and portability. We have developed an optical cavity-based biosensor (OCB) as a promising solution due to its label-free detection, high sensitivity, real-time monitoring, multiplexing capability, and versatility. The OCB consists of an optical cavity structure (OCS), optical components, and a low-cost camera. The OCS is created by two partially reflective surfaces separated by a small gap, where the interaction between target analytes and immobilized receptors leads to a shift in the resonance transmission spectrum, caused by minute changes in the local refractive index (RI). In our previous work, we successfully detected these small changes with a simple OCS and cost-effective components using a differential detection method. Building upon these achievements, this study focuses on optimizing the OCS, improving the camera settings, and enhancing the differential detection approach. By increasing the reflectance of the surfaces and optimizing the optical cavity widths correspondingly, we achieved an improved limit of detection (LOD). We also investigated how the charge-coupled device (CCD) camera shutter time affects the LOD. Additionally, we introduced a new differential equation to further enhance the sensitivity of our system. Through these advancements, we could improve the LOD of the OCB by 7.2 times, specifically for an OCS with a cavity thickness of 9.881 m and a silver thickness of 46.87 nm. These findings not only contribute to the ongoing effort of optimizing the OCB, but also pave the way for the development of advanced point-of-care biosensors with enhanced detection capabilities.

Keywords

References

  1. Nat Biotechnol. 2019 Apr;37(4):389-406 [PMID: 30804534]
  2. Chem Soc Rev. 2017 Jan 23;46(2):366-388 [PMID: 27841420]
  3. J Anal Methods Chem. 2019 Oct 23;2019:2179718 [PMID: 31886019]
  4. Expert Rev Mol Diagn. 2014 Mar;14(2):225-44 [PMID: 24524681]
  5. Front Chem. 2020 Oct 16;8:586702 [PMID: 33195085]
  6. Sensors (Basel). 2019 May 12;19(9): [PMID: 31083614]
  7. Opt Quantum Electron. 2023;55(2):164 [PMID: 36618533]
  8. Biosensors (Basel). 2023 Mar 01;13(3): [PMID: 36979545]
  9. Anal Bioanal Chem. 2020 May;412(14):3317-3349 [PMID: 32313998]
  10. Biosensors (Basel). 2020 Feb 12;10(2): [PMID: 32059538]
  11. Proteomics. 2011 Feb;11(4):535-53 [PMID: 21243637]
  12. Opt Express. 2018 Jul 23;26(15):18982-18989 [PMID: 30114158]
  13. Biosensors (Basel). 2022 Jun 06;12(6): [PMID: 35735540]
  14. Sci Rep. 2022 Apr 1;12(1):5548 [PMID: 35365740]
  15. Front Chem. 2020 May 27;8:517 [PMID: 32574316]
  16. Appl Opt. 2016 Jan 10;55(2):395-9 [PMID: 26835777]
  17. Biosens Bioelectron. 2018 Jan 15;99:122-135 [PMID: 28750336]
  18. Future Sci OA. 2019 Nov 29;6(2):FSO439 [PMID: 32025328]
  19. Biosensors (Basel). 2020 Dec 24;11(1): [PMID: 33374119]
  20. Opt Express. 2017 May 15;25(10):11244-11253 [PMID: 28788806]
  21. Sensors (Basel). 2022 Aug 27;22(17): [PMID: 36080926]
  22. Micromachines (Basel). 2020 Mar 30;11(4): [PMID: 32235546]
  23. Nat Microbiol. 2019 Jan;4(1):46-54 [PMID: 30546093]
  24. Anal Chim Acta. 2023 Apr 29;1252:341051 [PMID: 36935139]

Grants

  1. R15 GM146233/NIGMS NIH HHS

Word Cloud

Created with Highcharts 10.0.0detectionopticalOCBOCSsensitivityLODbiosensorcavitycameradifferentialoptimizingbiosensorsimprovedcavity-basedcomponentslow-costsurfacessmallchangesrefractiveindexRIlimitalsothicknesspoint-of-carerapidadvancementtechnologyrevolutionizedhealthcareofferingspecificityportabilitydevelopedpromisingsolutionduelabel-freehighreal-timemonitoringmultiplexingcapabilityversatilityconsistsstructurecreatedtwopartiallyreflectiveseparatedgapinteractiontargetanalytesimmobilizedreceptorsleadsshiftresonancetransmissionspectrumcausedminutelocalpreviousworksuccessfullydetectedsimplecost-effectiveusingmethodBuildinguponachievementsstudyfocusesimprovingsettingsenhancingapproachincreasingreflectancewidthscorrespondinglyachievedinvestigatedcharge-coupleddeviceCCDshuttertimeaffectsAdditionallyintroducednewequationenhancesystemadvancementsimprove72timesspecifically9881msilver4687nmfindingscontributeongoingeffortpavewaydevelopmentadvancedenhancedcapabilitiesOptimizingOpticalCavity-BasedBiosensorEnhancedSensitivityHighlow

Similar Articles

Cited By