Portable polygraphic device (Somnocheck micro CARDIO) provides accurate diagnostic information in psychiatric patients at risk for obstructive sleep apnoea: an observational cohort study.

Maximilian Bailer, Eva M Stein, Maximilian I Sprügel, Stefan Mestermann, Philipp Spitzer, Janine Utz, Sabine Zirlik, Florian S Fuchs, Johannes Kornhuber
Author Information
  1. Maximilian Bailer: Department of Psychiatry and Psychotherapy, Friedrich-Alexander-Universität Erlangen-Nürnberg, Schwabachanlage 6, 91054, Erlangen, Germany. maximilian.bailer@uk-erlangen.de.
  2. Eva M Stein: Department of Psychiatry and Psychotherapy, Friedrich-Alexander-Universität Erlangen-Nürnberg, Schwabachanlage 6, 91054, Erlangen, Germany.
  3. Maximilian I Sprügel: Department of Psychiatry and Psychotherapy, Friedrich-Alexander-Universität Erlangen-Nürnberg, Schwabachanlage 6, 91054, Erlangen, Germany.
  4. Stefan Mestermann: Department of Psychiatry and Psychotherapy, Friedrich-Alexander-Universität Erlangen-Nürnberg, Schwabachanlage 6, 91054, Erlangen, Germany.
  5. Philipp Spitzer: Department of Psychiatry and Psychotherapy, Friedrich-Alexander-Universität Erlangen-Nürnberg, Schwabachanlage 6, 91054, Erlangen, Germany.
  6. Janine Utz: Department of Psychiatry and Psychotherapy, Friedrich-Alexander-Universität Erlangen-Nürnberg, Schwabachanlage 6, 91054, Erlangen, Germany.
  7. Sabine Zirlik: Department of Internal Medicine 1, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany.
  8. Florian S Fuchs: Department of Internal Medicine 1, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany.
  9. Johannes Kornhuber: Department of Psychiatry and Psychotherapy, Friedrich-Alexander-Universität Erlangen-Nürnberg, Schwabachanlage 6, 91054, Erlangen, Germany.

Abstract

BACKGROUND: Symptoms of obstructive sleep apnoea (OSA) overlap significantly with those of psychiatric disorders, making accurate diagnosis of OSA challenging within psychiatric settings. Diagnosing OSA in psychiatric patients is crucial because untreated OSA can exacerbate psychiatric symptoms, reduce treatment efficacy, and impair overall quality of life. This study aimed to determine the diagnostic accuracy of a readily accessible procedure for psychiatric patients in a real-world clinical setting by comparing the Somnocheck micro CARDIO (SCm) portable cardiorespiratory polygraphy device with the gold standard polysomnography (PSG).
METHODS: This observational cohort study included consecutive psychiatric patients at intermediate to high risk for OSA based on screening with the STOP-Bang questionnaire, admitted to a single tertiary care centre between June 1, 2016 and December 31, 2022. The Apnoea-Hypopnoea-Index (AHI), Apnoea-Index (AI), Oxygen-Desaturation-Index (ODI), and minimum oxygen saturation were measured sequentially by SCm and PSG.
RESULTS: A total of 57 patients were analysed (median age 62.0 [Interquartile Range (IQR), 51.5-72.5] years; 34 [59.6%] men). Regarding AHI, no significant differences (AHI measured by PSG, median, 16.6 [IQR, 6.2-26.7] vs. AHI measured by SCm, median, 14.9 [IQR, 10.0-22.8]; p = 0.812; r = 0.71) were found between SCm and PSG. AI, ODI and minimum oxygen saturation differed significantly between SCm and PSG. Using optimised cut-off values (any OSA: AHI ≥ 9.25), SCm showed high sensitivity (0.894) and high specificity (0.800) for the diagnosis of OSA, with an area under the receiver operating characteristic curve of 0.877.
CONCLUSIONS: This study found that the SCm portable device was accurate in identifying psychiatric patients with OSA. AHI measurement by SCm provided reliable diagnostic performance in comparison with the gold standard polysomnography. These findings support the integration of polygraphic measurements into the routine sleep assessment of psychiatric patients. Early and accurate diagnosis of OSA in this population can significantly improve the management of both sleep disorders and psychiatric conditions, potentially enhancing overall treatment outcomes and quality of life for these patients.

Keywords

References

  1. Sleep Med. 2020 Aug;72:50-58 [PMID: 32544796]
  2. J Clin Sleep Med. 2021 Nov 1;17(11):2171-2178 [PMID: 34666884]
  3. Cancer. 1950 Jan;3(1):32-5 [PMID: 15405679]
  4. Respir Care. 2021 Mar;66(3):384-390 [PMID: 33023999]
  5. Sleep. 2003 Nov 1;26(7):907-13 [PMID: 14655928]
  6. J Sleep Res. 2017 Dec;26(6):782-788 [PMID: 28548301]
  7. Am J Respir Crit Care Med. 2002 May 1;165(9):1217-39 [PMID: 11991871]
  8. Sleep Med Rev. 2018 Oct;41:149-160 [PMID: 30149930]
  9. Schizophr Res. 2016 Jan;170(1):222-5 [PMID: 26621003]
  10. J Sleep Res. 2016 Dec;25(6):731-738 [PMID: 27242272]
  11. Nat Rev Dis Primers. 2015 Jun 25;1:15015 [PMID: 27188535]
  12. Chest. 2016 Mar;149(3):631-8 [PMID: 26378880]
  13. Respiration. 2001;68(3):307-12 [PMID: 11416253]
  14. Cureus. 2019 Apr 28;11(4):e4560 [PMID: 31281744]
  15. J Clin Sleep Med. 2007 Dec 15;3(7):737-47 [PMID: 18198809]
  16. Depress Anxiety. 2021 May;38(5):498-507 [PMID: 33368782]
  17. Am J Epidemiol. 2001 Jul 1;154(1):50-9 [PMID: 11434366]
  18. Med Sci Sports Exerc. 2019 Jul;51(7):1538-1557 [PMID: 30789439]
  19. J Med Internet Res. 2023 Jul 26;25:e47735 [PMID: 37494079]
  20. J Clin Monit Comput. 2019 Apr;33(2):341-345 [PMID: 29749570]
  21. Syst Rev. 2020 Jan 16;9(1):17 [PMID: 31948489]
  22. Respiration. 2009;77(1):32-7 [PMID: 18957843]
  23. Sci Rep. 2017 Apr 04;8:45901 [PMID: 28374832]
  24. Maturitas. 2020 Dec;142:45-54 [PMID: 33158487]
  25. Laryngoscope. 2006 Jun;116(6):859-64 [PMID: 16735890]
  26. Sleep Breath. 2022 Sep;26(3):1053-1078 [PMID: 34406554]
  27. Sleep. 2012 Jun 01;35(6):757-67 [PMID: 22654195]
  28. J Clin Sleep Med. 2011 Oct 15;7(5):531-48 [PMID: 22003351]
  29. PLOS Digit Health. 2022 Aug 22;1(8):e0000051 [PMID: 36812630]
  30. J Clin Sleep Med. 2017 Mar 15;13(3):479-504 [PMID: 28162150]
  31. Med Sci Monit. 2011 Feb 25;17(3):CR159-64 [PMID: 21358603]
  32. Am J Epidemiol. 2013 May 1;177(9):1006-14 [PMID: 23589584]
  33. Sensors (Basel). 2020 Dec 08;20(24): [PMID: 33302407]
  34. Eur Respir Rev. 2013 Sep 1;22(129):312-24 [PMID: 23997059]
  35. Sleep Breath. 2019 Mar;23(1):13-24 [PMID: 29687190]
  36. Anesthesiology. 2008 May;108(5):812-21 [PMID: 18431116]
  37. Sleep. 2005 Nov;28(11):1405-11 [PMID: 16335330]
  38. Depress Anxiety. 2016 Dec;33(12):1107-1113 [PMID: 27636232]
  39. Pak J Med Sci. 2016 Mar-Apr;32(2):471-5 [PMID: 27182264]
  40. J Clin Sleep Med. 2012 Oct 15;8(5):527-33 [PMID: 23066364]
  41. Eur Respir Rev. 2022 May 4;31(164): [PMID: 35508332]
  42. J Sleep Res. 2023 Aug;32(4):e13819 [PMID: 36807680]
  43. J Clin Sleep Med. 2015 Jan 15;11(2):165-75 [PMID: 25406268]
  44. J Sleep Res. 2019 Oct;28(5):e12770 [PMID: 30272383]
  45. Sleep Med Rev. 2023 Apr;68:101743 [PMID: 36657366]
  46. Sleep Med Rev. 2017 Aug;34:70-81 [PMID: 27568340]
  47. Sleep Breath. 2022 Mar;26(1):195-204 [PMID: 33942208]
  48. Am J Respir Crit Care Med. 2022 Mar 1;205(5):563-569 [PMID: 34904935]
  49. Sleep Breath. 2018 Sep;22(3):593-611 [PMID: 29318566]
  50. Chest. 2001 Dec;120(6):1923-9 [PMID: 11742923]

MeSH Term

Humans
Sleep Apnea, Obstructive
Male
Female
Middle Aged
Polysomnography
Aged
Mental Disorders
Cohort Studies
Sensitivity and Specificity

Word Cloud

Created with Highcharts 10.0.0psychiatricOSApatientsSCmPSGAHIsleepaccuratestudy0obstructivesignificantlydisordersdiagnosisdiagnosticdevicehighmeasuredmedianapnoeacantreatmentoverallqualitylifeSomnocheckmicroCARDIOportablecardiorespiratorypolygraphygoldstandardpolysomnographyobservationalcohortriskAIODIminimumoxygensaturation6[IQR9foundpolygraphicPortableMentalSleepBACKGROUND:SymptomsoverlapmakingchallengingwithinsettingsDiagnosingcrucialuntreatedexacerbatesymptomsreduceefficacyimpairaimeddetermineaccuracyreadilyaccessibleprocedurereal-worldclinicalsettingcomparingMETHODS:includedconsecutiveintermediatebasedscreeningSTOP-BangquestionnaireadmittedsingletertiarycarecentreJune12016December312022Apnoea-Hypopnoea-IndexApnoea-IndexOxygen-Desaturation-IndexsequentiallyRESULTS:total57analysedage62[InterquartileRangeIQR515-725]years34[596%]menRegardingsignificantdifferences162-267]vs14100-228]p = 0812r = 071differedUsingoptimisedcut-offvaluesOSA:25showedsensitivity894specificity800areareceiveroperatingcharacteristiccurve877CONCLUSIONS:identifyingmeasurementprovidedreliableperformancecomparisonfindingssupportintegrationmeasurementsroutineassessmentEarlypopulationimprovemanagementconditionspotentiallyenhancingoutcomesprovidesinformationapnoea:healthPolysomnography

Similar Articles

Cited By