Characteristics of high-echoic objects in the hepatic vessels of patients with cardiopulmonary arrest: a prospective cohort study.

Shinju Arata, Junichi Suzuki, Yoshihiro Moriwaki, Noriyuki Suzuki, Masayuki Iwashita, Mitsugi Sugiyama, Satoshi Morita
Author Information
  1. Shinju Arata: Critical Care and Emergency Centre, Yokohama City University School of Medicine, 4-57 Urafune-cho, Minami-ku, Yokohama 232-0024, Japan. s_arata@yokohama-cu.ac.jp

Abstract

BACKGROUND: High-echoic objects in the hepatic vessels of patients with cardiopulmonary arrest (CPA) are frequently detected by ultrasonography.
OBJECTIVE: To demonstrate this phenomenon and clarify its clinical characteristics.
METHODS: In a tertiary care academic medical centre, 203 CPA patients were evaluated by ultrasonography. CT determined the origin and location of high-echoic objects detected in the liver. The frequency and characteristics of this phenomenon were investigated. The background, laboratory data and survival rate were compared between patients with and without high-echoic objects.
RESULTS: High-echoic objects were seen in 73 (36.0%) patients and could clearly be detected in the hepatic veins of 41 (56.2%) patients. CT confirmed that these were gas in 27 of 53 patients, and were clearly visible in the hepatic veins in 12 (44.4%) patients. Hepatic portal venous gas was not identified. Compared to patients without high-echoic objects, witnessed arrest (p<0.001), bystander cardiopulmonary resuscitation (p=0.005), ventricular fibrillation or pulseless electrical activity (p=0.012) and return of spontaneous circulation (p=0.018) were significantly less frequent in patients with high-echoic objects. These patients had a lower incidence of survival to discharge (1.4% vs 7.7%, p=0.100). Multivariate analysis showed that absence of high-echoic objects was a marginally significant factor in association with return of spontaneous circulation (p=0.052).
CONCLUSIONS: High-echoic objects were often observed on ultrasonography in CPA patients; these objects were considered hepatic venous gas. The presence of high-echoic objects may be a poor prognostic sign in patients with CPA.

MeSH Term

Aged
Female
Gases
Heart Arrest
Hepatic Veins
Humans
Male
Middle Aged
Multivariate Analysis
Prospective Studies
Survival Rate
Tomography, X-Ray Computed
Ultrasonography

Chemicals

Gases

Word Cloud

Created with Highcharts 10.0.0patientsobjectshigh-echoichepaticp=0CPAHigh-echoiccardiopulmonarydetectedultrasonographygasvesselsarrestphenomenoncharacteristicsCTsurvivalwithoutclearlyveins4%venousreturnspontaneouscirculationBACKGROUND:frequentlyOBJECTIVE:demonstrateclarifyclinicalMETHODS:tertiarycareacademicmedicalcentre203evaluateddeterminedoriginlocationliverfrequencyinvestigatedbackgroundlaboratorydataratecomparedRESULTS:seen73360%41562%confirmed2753visible1244HepaticportalidentifiedComparedwitnessedp<0001bystanderresuscitation005ventricularfibrillationpulselesselectricalactivity012018significantlylessfrequentlowerincidencedischarge1vs77%100Multivariateanalysisshowedabsencemarginallysignificantfactorassociation052CONCLUSIONS:oftenobservedconsideredpresencemaypoorprognosticsignCharacteristicsarrest:prospectivecohortstudy

Similar Articles

Cited By (1)