Lipidomic analysis of biological samples: Comparison of liquid chromatography, supercritical fluid chromatography and direct infusion mass spectrometry methods.

Miroslav Lísa, Eva Cífková, Maria Khalikova, Magdaléna Ovčačíková, Michal Holčapek
Author Information
  1. Miroslav Lísa: Department of Analytical Chemistry, Faculty of Chemical Technology, University of Pardubice, Studentská 573, 53210 Pardubice, Czech Republic. Electronic address: miroslav.lisa@gmail.com.
  2. Eva Cífková: Department of Analytical Chemistry, Faculty of Chemical Technology, University of Pardubice, Studentská 573, 53210 Pardubice, Czech Republic.
  3. Maria Khalikova: Department of Analytical Chemistry, Faculty of Chemical Technology, University of Pardubice, Studentská 573, 53210 Pardubice, Czech Republic.
  4. Magdaléna Ovčačíková: Department of Analytical Chemistry, Faculty of Chemical Technology, University of Pardubice, Studentská 573, 53210 Pardubice, Czech Republic.
  5. Michal Holčapek: Department of Analytical Chemistry, Faculty of Chemical Technology, University of Pardubice, Studentská 573, 53210 Pardubice, Czech Republic.

Abstract

Lipidomic analysis of biological samples in a clinical research represents challenging task for analytical methods given by the large number of samples and their extreme complexity. In this work, we compare direct infusion (DI) and chromatography - mass spectrometry (MS) lipidomic approaches represented by three analytical methods in terms of comprehensiveness, sample throughput, and validation results for the lipidomic analysis of biological samples represented by tumor tissue, surrounding normal tissue, plasma, and erythrocytes of kidney cancer patients. Methods are compared in one laboratory using the identical analytical protocol to ensure comparable conditions. Ultrahigh-performance liquid chromatography/MS (UHPLC/MS) method in hydrophilic interaction liquid chromatography mode and DI-MS method are used for this comparison as the most widely used methods for the lipidomic analysis together with ultrahigh-performance supercritical fluid chromatography/MS (UHPSFC/MS) method showing promising results in metabolomics analyses. The nontargeted analysis of pooled samples is performed using all tested methods and 610 lipid species within 23 lipid classes are identified. DI method provides the most comprehensive results due to identification of some polar lipid classes, which are not identified by UHPLC and UHPSFC methods. On the other hand, UHPSFC method provides an excellent sensitivity for less polar lipid classes and the highest sample throughput within 10min method time. The sample consumption of DI method is 125 times higher than for other methods, while only 40μL of organic solvent is used for one sample analysis compared to 3.5mL and 4.9mL in case of UHPLC and UHPSFC methods, respectively. Methods are validated for the quantitative lipidomic analysis of plasma samples with one internal standard for each lipid class. Results show applicability of all tested methods for the lipidomic analysis of biological samples depending on the analysis requirements.

Keywords

MeSH Term

Chromatography, Liquid
Chromatography, Supercritical Fluid
Computational Biology
Lipids
Mass Spectrometry
Reproducibility of Results

Chemicals

Lipids

Word Cloud

Created with Highcharts 10.0.0analysismethodsmethodsampleslipidomiclipidbiologicalchromatographysampleUHPSFCLipidomicanalyticalinfusionDIspectrometryresultsoneliquidusedclassesUHPLCdirectmassrepresentedthroughputtissueplasmaMethodscomparedusingchromatography/MSsupercriticalfluidtestedwithinidentifiedprovidespolarclinicalresearchrepresentschallengingtaskgivenlargenumberextremecomplexityworkcompare-MSapproachesthreetermscomprehensivenessvalidationtumorsurroundingnormalerythrocyteskidneycancerpatientslaboratoryidenticalprotocolensurecomparableconditionsUltrahigh-performanceUHPLC/MShydrophilicinteractionmodeDI-MScomparisonwidelytogetherultrahigh-performanceUHPSFC/MSshowingpromisingmetabolomicsanalysesnontargetedpooledperformed610species23comprehensivedueidentificationhandexcellentsensitivitylesshighest10mintimeconsumption125timeshigher40μLorganicsolvent35mL49mLcaserespectivelyvalidatedquantitativeinternalstandardclassResultsshowapplicabilitydependingrequirementssamples:ComparisonDirectLipidomicsMass

Similar Articles

Cited By