A novel ultrasonic method for evaluation of blood clotting parameters.

Vacis Tatarunas, Algirdas Voleisis, Reimondas Sliteris, Rymantas Kazys, Liudas Mazeika, Vaiva Lesauskaite
Author Information
  1. Vacis Tatarunas: Laboratory of Molecular Cardiology, Institute of Cardiology, Lithuanian University of Health Sciences, Sukileliu 15, 50009, Kaunas, Lithuania. vacis.tatarunas@lsmuni.lt. ORCID
  2. Algirdas Voleisis: Ultrasound Institute, Kaunas University of Technology, K. Baršausko g. 59, Kaunas, Lithuania.
  3. Reimondas Sliteris: Ultrasound Institute, Kaunas University of Technology, K. Baršausko g. 59, Kaunas, Lithuania.
  4. Rymantas Kazys: Ultrasound Institute, Kaunas University of Technology, K. Baršausko g. 59, Kaunas, Lithuania.
  5. Liudas Mazeika: Ultrasound Institute, Kaunas University of Technology, K. Baršausko g. 59, Kaunas, Lithuania.
  6. Vaiva Lesauskaite: Laboratory of Molecular Cardiology, Institute of Cardiology, Lithuanian University of Health Sciences, Sukileliu 15, 50009, Kaunas, Lithuania.

Abstract

PURPOSE: For long time, blood clot retraction was measured only by thromboelastographic or platelet contractile force measurement techniques. The purpose of the present study was development of a novel ultrasonic method based on simultaneous monitoring of variations in the ultrasound velocity and the frequency spectrum of the signal propagating in clotting blood and its application for automatic evaluation of blood clotting parameters.
METHODS: Simultaneous measurement of ultrasound velocity and variations in the frequency spectrum of wideband ultrasonic signals in clotting blood samples was performed. All measurements were performed in pulse-echo mode. Standard clinical data were obtained using routine clinical laboratory methods.
RESULTS: The amplitudes of ultrasonic signals during native blood coagulation varied up to ten times for different frequencies. The measurement results of the start and duration of blood clot retraction differed between patient samples: different components of the blood coagulation system had significant impact on the blood clot retraction process.
CONCLUSIONS: Our results showed that during blood clotting, the ultrasound velocity and variations in frequency spectrum should be used simultaneously to determine the beginning and duration of blood clot retraction. Our results also showed that blood clot retraction is controlled by the activity of factor XIII.

Keywords

References

  1. Ultrasound Med Biol. 2008 Feb;34(2):252-64 [PMID: 18077082]
  2. Haemophilia. 2008 Nov;14(6):1190-200 [PMID: 19141159]
  3. Ultrasonics. 2002 May;40(1-8):101-7 [PMID: 12159914]
  4. Eur Heart J. 2015 Oct 21;36(40):2696-705 [PMID: 26306399]
  5. Physiol Meas. 1997 May;18(2):129-43 [PMID: 9183807]
  6. Blood Coagul Fibrinolysis. 2014 Jun;25(4):369-74 [PMID: 24418943]
  7. Inflammation. 2012 Apr;35(2):429-35 [PMID: 21499712]
  8. Atherosclerosis. 2012 Sep;224(1):213-7 [PMID: 22818563]
  9. Ultrasound Med Biol. 2010 Feb;36(2):295-305 [PMID: 20045589]
  10. Atherosclerosis. 2011 May;216(1):151-6 [PMID: 21353223]
  11. Lab Chip. 2010 Apr 21;10(8):991-8 [PMID: 20358105]
  12. J Clin Ultrasound. 1984 Mar-Apr;12(3):147-53 [PMID: 6423688]
  13. PLoS One. 2014 Jul 02;9(7):e100239 [PMID: 24988537]
  14. Blood. 2000 Oct 1;96(7):2479-86 [PMID: 11001900]
  15. J Acoust Soc Am. 2009 Jan;125(1):530-8 [PMID: 19173438]
  16. Arterioscler Thromb Vasc Biol. 1998 Mar;18(3):487-92 [PMID: 9514419]
  17. Sci China C Life Sci. 2008 Sep;51(9):814-20 [PMID: 18726528]
  18. J Thromb Haemost. 2005 Sep;3(9):2015-21 [PMID: 16102108]
  19. Biorheology. 1997 Nov-Dec;34(6):443-70 [PMID: 9640358]
  20. Eur Heart J. 2012 Oct;33(20):2569-619 [PMID: 22922416]
  21. Ultrasound Med Biol. 2005 Nov;31(11):1567-73 [PMID: 16286034]
  22. BMC Med Genet. 2010 Feb 18;11:28 [PMID: 20167083]
  23. Circulation. 2000 Mar 7;101(9):1013-8 [PMID: 10704169]
  24. Ultrasonics. 1978 Jan;16(1):33-6 [PMID: 622750]
  25. J Thromb Thrombolysis. 2014 Oct;38(3):380-7 [PMID: 24510702]
  26. Blood. 2013 Mar 7;121(10):1712-9 [PMID: 23305734]

Grants

  1. UKOAG/Lithuanian University of Health Sciences
  2. UKOAGII/Lithuanian University of Health Sciences
  3. UKOAG/Kaunas University of Technology
  4. UKOAGII/Kaunas University of Technology

MeSH Term

Adult
Blood Coagulation
Blood Coagulation Tests
Equipment Design
Female
Humans
Male
Ultrasonic Waves
Ultrasonography

Word Cloud

Created with Highcharts 10.0.0bloodclotretractionclottingultrasonicvelocityspectrummeasurementvariationsultrasoundfrequencyresultsnovelmethodevaluationparameterssignalsperformedclinicalcoagulationdifferentdurationshowedXIIIUltrasoundPURPOSE:longtimemeasuredthromboelastographicplateletcontractileforcetechniquespurposepresentstudydevelopmentbasedsimultaneousmonitoringsignalpropagatingapplicationautomaticMETHODS:Simultaneouswidebandsamplesmeasurementspulse-echomodeStandarddataobtainedusingroutinelaboratorymethodsRESULTS:amplitudesnativevariedtentimesfrequenciesstartdifferedpatientsamples:componentssystemsignificantimpactprocessCONCLUSIONS:usedsimultaneouslydeterminebeginningalsocontrolledactivityfactorBloodFactorFrequency

Similar Articles

Cited By (1)