Two cases of contact allergic reactions to Finn Chamber AQUA test chambers.

Nils Hamnerius, Martin Mowitz
Author Information
  1. Nils Hamnerius: Department of Occupational and Environmental Dermatology, Lund University, Skåne University Hospital, Malmö, Sweden. ORCID
  2. Martin Mowitz: Department of Occupational and Environmental Dermatology, Lund University, Skåne University Hospital, Malmö, Sweden. ORCID

Abstract

No abstract text available.

Keywords

References

  1. Clemmensen O, Knudsen HE. Contact sensitivity to aluminium in a patient hyposensitized with aluminium precipitated grass pollen. Contact Dermatitis. 1980;6:305-308.
  2. Fischer T, Rystedt I. A case of contact sensitivity to aluminium. Contact Dermatitis. 1982;8:343.
  3. Meding B, Augustsson A, Hansson C. Patch test reaction to aluminium. Contact Dermatitis. 1984;10:107.
  4. Kotovirta ML, Salo OP, Visa-Tolvanen K. Contact sensitivity to aluminum. Contact Dermatitis. 1984;11:135.
  5. Cox NH, Moss C, Forsyth A. Allergy to non-toxoid constituents of vaccines and implications for patch testing. Contact Dermatitis. 1988;18:143-146.
  6. Tosti A, Vincenzi C, Peluso AM. Accidental diagnosis of aluminium sensitivity with Finn chambers. Contact Dermatitis. 1990;23:48-49.
  7. O'Driscoll JB, Beck MB, Kesseler ME, Ford G. Contact sensitivity to aluminium acetate eardrops. Contact Dermatitis. 1991;24:156-157.
  8. Dwyer CM, Kerr RE. Contact allergy to aluminium in 2 brothers. Contact Dermatitis. 1993;29:36-38.
  9. Bajaj AK, Gupta SC, Pandey RK, Misra K, Rastogi S, Chatterji AK. Aluminium contact sensitivity. Contact Dermatitis. 1997;37:307-308.
  10. Akyol A, Boyvat A, Kundakçi N. Contact sensitivity to aluminum. Int J Dermatol. 2004;43:942-943.
  11. Matura M, Anveden Berglind I, Ohlén A. An unexpected case of contact allergy to aluminium. Contact Dermatitis. 2012;66(suppl 2):S40.
  12. Johansen JD, Aalto-Korte K, Agner T, et al. European Society of Contact Dermatitis guideline for diagnostic patch testing-recommendations on best practice. Contact Dermatitis. 2015;73:195-221.
  13. Mowitz M, Herman A, Baeck M, et al. N,N-dimethylacrylamide-a new sensitizer in the FreeStyle libre glucose sensor. Contact Dermatitis. 2019;81:27-31.
  14. SmartPractice webpage. https://www.smartpractice.com/shop/wa/category?cn=Products-Finn-Chambers&id=508223&m=SPA. Accessed December 30, 2018.
  15. King N, Moffitt D. Allergic contact dermatitis secondary to the use of aluminium Finn Chambers. Contact Dermatitis. 2018;78:365-366.
  16. Sánchez-Gilo A, Gómez-de la Fuente E, Vicente-Martín FJ. Allergic contact dermatitis caused by Finn Chambers AQUA in two patients. Contact Dermatitis. 2019;80:246-247.
  17. Sasseville D, Tennstedt D, Lachapelle JM. Allergic contact dermatitis from hydrocolloid dressings. Am J Contact Dermat. 1997;8:236-238.
  18. Panasiti I, Crisafulli G, Salzano G, Pajno GB. Allergic contact dermatitis and diabetes medical devices: 2 clinical cases. Contact Dermatitis. 2018;79:178-180.

MeSH Term

Adhesives
Bandages
Bandages, Hydrocolloid
Child
Dermatitis, Allergic Contact
Female
Humans
Patch Tests

Chemicals

Adhesives

Word Cloud

Created with Highcharts 10.0.0contactallergicFinnAQUAtestTwocasesreactionsChamberchambersChambersadhesivedermatitiscasereportmodifiedcolophoniumpatch

Similar Articles

Cited By (1)