New pathological illuminations on 3D transillumination transesophageal echocardiography imaging.

Chieh-Ju Chao, Deepa R Mandale, Tasneem Z Naqvi
Author Information
  1. Chieh-Ju Chao: Echocardiography Laboratory, Department of Cardiovascular Medicine, Mayo Clinic, Scottsdale, AZ, USA. ORCID
  2. Deepa R Mandale: Echocardiography Laboratory, Department of Cardiovascular Medicine, Mayo Clinic, Scottsdale, AZ, USA.
  3. Tasneem Z Naqvi: Echocardiography Laboratory, Department of Cardiovascular Medicine, Mayo Clinic, Scottsdale, AZ, USA. ORCID

Abstract

The use of 3D technology has significantly improved the diagnostic accuracy of echocardiography by overcoming the limitation of 2D echocardiography. Transillumination 3D image post processing technique enhances shadows and contrast of cardiac structures with a movable virtual light source improving further the clarity and detail provided by conventional 3D imaging. In this report, we present 3 cases, one of mobile atherosclerotic aortic root plaque, another of small thrombi on ICD lead, and a third case of bicuspid aortic valve perforation due to infective endocarditis in whom TEE 3D transillumination further improved the diagnostic quality of conventional 3D imaging and lead to accurate clinical diagnosis.

Keywords

References

  1. Lang RM, Badano LP, Tsang W, et al EAE/ASE recommendations for image acquisition and display using three-dimensional echocardiography. J Am Soc Echocardiog. 2012;25(1):3-46.
  2. Naqvi TZ. Echocardiography in transcatheter aortic (Core)Valve implantation: Part 2-Transesophageal echocardiography. Echocardiography. 2018;35(7):1020-1041.
  3. Genovese D, Addetia K, Kebed K, et al First clinical experience with 3-dimensional echocardiographic transillumination rendering. Jacc Cardiovasc Imaging. 2019;12(9):1868-1871.

MeSH Term

Echocardiography, Three-Dimensional
Echocardiography, Transesophageal
Endocarditis
Humans
Lighting
Transillumination

Word Cloud

Created with Highcharts 10.0.0echocardiography3Dimagingtransesophagealimproveddiagnosticconventionalaorticleadtransilluminationusetechnologysignificantlyaccuracyovercominglimitation2DTransilluminationimagepostprocessingtechniqueenhancesshadowscontrastcardiacstructuresmovablevirtuallightsourceimprovingclaritydetailprovidedreportpresent3casesonemobileatheroscleroticrootplaqueanothersmallthrombiICDthirdcasebicuspidvalveperforationdueinfectiveendocarditisTEEqualityaccurateclinicaldiagnosisNewpathologicalilluminationslivethree-dimensionaltransthoracicthreedimensional

Similar Articles

Cited By