Feasibility of Proton Range Estimation with Prompt Gamma Imaging in Proton Therapy of Lung Cancer: Monte Carlo Study.

Elham Rohollahpour, Hadi Taleshi Ahangari
Author Information
  1. Elham Rohollahpour: Department of Medical Physics, School of Medicine, Semnan University of Medical Sciences, Semnan, Iran.
  2. Hadi Taleshi Ahangari: Department of Medical Physics, School of Medicine, Semnan University of Medical Sciences, Semnan, Iran.

Abstract

Context: Using prompt gamma (PG) ray is proposed as a promising solution for monitoring in proton therapy. Despite significant and diverse approaches explored over the past two decades, challenges still persist for more effective utilization.
Aims: The feasibility of estimating proton range with PG imaging (PGI) as an online imaging guide in an anthropomorphic phantom with lung cancer was investigated through GATE/GEANT4 Monte Carlo simulation.
Setting and Design: Once the GATE code was validated for use as a simulation tool, the gamma energy spectra of NURBS-based cardiac-torso (NCAT) and polymethyl methacrylate phantoms, representing heterogeneous and homogeneous phantoms respectively, were compared with the gamma emission lines known in nuclear interactions with tissue elements. A 5-mm radius spherical tumor in the lung region of an NCAT phantom, without any physiological or morphological changes, was simulated.
Subjects and Methods: The proton pencil beam source was defined as a function of the tumor size to encompass the tumor volume. The longitudinal spatial correlation between the proton dose deposition and the distribution of detected PG rays by the multi-slit camera was assessed for proton range estimation. The simulations were conducted for both 10 and 10 protons.
Results: The deviation between the proton range and the range estimated by PGI following proton beam irradiation to the center of the lung tumor was determined by evaluating the longitudinal profiles at the 80% fall-off point, measuring 1.9 mm for 10 protons and 4.5 mm for 10 protons.
Conclusions: The accuracy of proton range estimation through PGI is greatly influenced by the number of incident protons and tissue characteristics. With 10 protons, it is feasible to utilize PGI as a real-time monitoring technique during proton therapy for lung cancer.

Keywords

References

  1. J Med Phys. 2014 Oct;39(4):212-8 [PMID: 25525308]
  2. Phys Med Biol. 2015 Sep 21;60(18):7085-99 [PMID: 26317610]
  3. Radiother Oncol. 2016 Feb;118(2):232-7 [PMID: 26774764]
  4. Phys Med Biol. 2012 Jun 7;57(11):3371-405 [PMID: 22572603]
  5. Front Oncol. 2016 Jun 27;6:156 [PMID: 27446802]
  6. Radiother Oncol. 2016 Mar;118(3):562-7 [PMID: 26627703]
  7. Phys Med Biol. 2010 Nov 21;55(22):6841-56 [PMID: 21048295]
  8. Med Phys. 2012 Apr;39(4):2100-7 [PMID: 22482631]
  9. Phys Med Biol. 2014 Dec 21;59(24):7653-74 [PMID: 25415207]
  10. Phys Med Biol. 2012 Sep 7;57(17):5459-72 [PMID: 22864267]
  11. Phys Med Biol. 2012 Jan 21;57(2):297-308 [PMID: 22156148]
  12. Phys Med Biol. 2016 Jan 21;61(2):855-71 [PMID: 26740512]
  13. Phys Med. 2017 Jan;33:197-206 [PMID: 28027864]
  14. Phys Med Biol. 2012 Jun 7;57(11):R99-117 [PMID: 22571913]
  15. Phys Med Biol. 2015 Jun 21;60(12):4915-46 [PMID: 26057053]
  16. J Cancer Res Ther. 2010 Jul-Sep;6(3):239-48 [PMID: 21119247]
  17. Phys Med Biol. 2015 Jun 21;60(12):4849-71 [PMID: 26057897]
  18. Phys Med Biol. 2012 Jun 21;57(12):3759-84 [PMID: 22617050]
  19. Phys Med Biol. 2016 Nov 7;61(21):7725-7743 [PMID: 27740939]
  20. J Cancer Res Ther. 2018 Jun;14(Supplement):S416-S420 [PMID: 29970699]
  21. Med Phys. 2013 Nov;40(11):111705 [PMID: 24320413]
  22. PLoS One. 2018 Mar 5;13(3):e0193904 [PMID: 29505589]
  23. Phys Med Biol. 2012 Jun 7;57(11):3537-53 [PMID: 22588144]
  24. Phys Med Biol. 2013 May 7;58(9):2879-99 [PMID: 23571094]
  25. Phys Med Biol. 2013 Aug 7;58(15):R131-60 [PMID: 23863203]

Word Cloud

Created with Highcharts 10.0.0protonrangelung10protonsgammaPGItumorPGimagingphantomcancerMonteCarlosimulationestimationpromptmonitoringtherapyNCATphantomstissuebeamlongitudinalmmProtonContext:UsingrayproposedpromisingsolutionDespitesignificantdiverseapproachesexploredpasttwodecadeschallengesstillpersisteffectiveutilizationAims:feasibilityestimatingonlineguideanthropomorphicinvestigatedGATE/GEANT4SettingDesign:GATEcodevalidatedusetoolenergyspectraNURBS-basedcardiac-torsopolymethylmethacrylaterepresentingheterogeneoushomogeneousrespectivelycomparedemissionlinesknownnuclearinteractionselements5-mmradiussphericalregionwithoutphysiologicalmorphologicalchangessimulatedSubjectsMethods:pencilsourcedefinedfunctionsizeencompassvolumespatialcorrelationdosedepositiondistributiondetectedraysmulti-slitcameraassessedsimulationsconductedResults:deviationestimatedfollowingirradiationcenterdeterminedevaluatingprofiles80%fall-offpointmeasuring1945Conclusions:accuracygreatlyinfluencednumberincidentcharacteristicsfeasibleutilizereal-timetechniqueFeasibilityRangeEstimationPromptGammaImagingTherapyLungCancer:StudyAnthropomorphic

Similar Articles

Cited By